# Copyright (c) 2023-2024 Arista Networks, Inc.
# Use of this source code is governed by the Apache License 2.0
# that can be found in the LICENSE file.
"""Test inputs for anta.tests.flow_tracking."""
from __future__ import annotations
from typing import Any
from anta.tests.flow_tracking import VerifyHardwareFlowTrackerStatus
from tests.units.anta_tests import test
DATA: list[dict[str, Any]] = [
{
"name": "success",
"test": VerifyHardwareFlowTrackerStatus,
"eos_data": [
{
"trackers": {
"FLOW-TRACKER": {
"active": True,
"inactiveTimeout": 60000,
"activeInterval": 300000,
"exporters": {"CV-TELEMETRY": {"localIntf": "Loopback0", "templateInterval": 3600000}},
}
},
"running": True,
},
{
"trackers": {
"HARDWARE-TRACKER": {
"active": True,
"inactiveTimeout": 60000,
"activeInterval": 300000,
"exporters": {"CV-TELEMETRY": {"localIntf": "Loopback0", "templateInterval": 3600000}},
}
},
"running": True,
},
],
"inputs": {"trackers": [{"name": "FLOW-TRACKER"}, {"name": "HARDWARE-TRACKER"}]},
"expected": {"result": "success"},
},
{
"name": "success-with-optional-field",
"test": VerifyHardwareFlowTrackerStatus,
"eos_data": [
{
"trackers": {
"FLOW-TRACKER": {
"active": True,
"inactiveTimeout": 60000,
"activeInterval": 300000,
"exporters": {"CV-TELEMETRY": {"localIntf": "Loopback0", "templateInterval": 3600000}},
}
},
"running": True,
},
{
"trackers": {
"HARDWARE-TRACKER": {
"active": True,
"inactiveTimeout": 60000,
"activeInterval": 300000,
"exporters": {"CVP-TELEMETRY": {"localIntf": "Loopback10", "templateInterval": 3600000}},
}
},
"running": True,
},
],
"inputs": {
"trackers": [
{
"name": "FLOW-TRACKER",
"record_export": {"on_inactive_timeout": 60000, "on_interval": 300000},
"exporters": [{"name": "CV-TELEMETRY", "local_interface": "Loopback0", "template_interval": 3600000}],
},
{
"name": "HARDWARE-TRACKER",
"record_export": {"on_inactive_timeout": 60000, "on_interval": 300000},
"exporters": [{"name": "CVP-TELEMETRY", "local_interface": "Loopback10", "template_interval": 3600000}],
},
]
},
"expected": {"result": "success"},
},
{
"name": "failure-flow-tracking-not-running",
"test": VerifyHardwareFlowTrackerStatus,
"eos_data": [{"trackers": {}, "running": False}],
"inputs": {"trackers": [{"name": "FLOW-TRACKER"}]},
"expected": {
"result": "failure",
"messages": ["Hardware flow tracking is not running."],
},
},
{
"name": "failure-tracker-not-configured",
"test": VerifyHardwareFlowTrackerStatus,
"eos_data": [
{
"trackers": {
"HARDWARE-TRACKER": {
"active": True,
"inactiveTimeout": 60000,
"activeInterval": 300000,
"exporters": {"CVP-TELEMETRY": {"localIntf": "Loopback10", "templateInterval": 3600000}},
}
},
"running": True,
}
],
"inputs": {"trackers": [{"name": "FLOW-Sample"}]},
"expected": {
"result": "failure",
"messages": ["Hardware flow tracker `FLOW-Sample` is not configured."],
},
},
{
"name": "failure-tracker-not-active",
"test": VerifyHardwareFlowTrackerStatus,
"eos_data": [
{
"trackers": {
"FLOW-TRACKER": {
"active": False,
"inactiveTimeout": 60000,
"activeInterval": 300000,
"exporters": {"CV-TELEMETRY": {"localIntf": "Loopback0", "templateInterval": 3600000}},
}
},
"running": True,
},
{
"trackers": {
"HARDWARE-TRACKER": {
"active": False,
"inactiveTimeout": 60000,
"activeInterval": 300000,
"exporters": {"CVP-TELEMETRY": {"localIntf": "Loopback10", "templateInterval": 3600000}},
}
},
"running": True,
},
],
"inputs": {
"trackers": [
{
"name": "FLOW-TRACKER",
"record_export": {"on_inactive_timeout": 60000, "on_interval": 300000},
"exporters": [{"name": "CV-TELEMETRY", "local_interface": "Loopback0", "template_interval": 3600000}],
},
{
"name": "HARDWARE-TRACKER",
"record_export": {"on_inactive_timeout": 60000, "on_interval": 300000},
"exporters": [{"name": "CVP-TELEMETRY", "local_interface": "Loopback10", "template_interval": 3600000}],
},
]
},
"expected": {
"result": "failure",
"messages": ["Hardware flow tracker `FLOW-TRACKER` is not active.", "Hardware flow tracker `HARDWARE-TRACKER` is not active."],
},
},
{
"name": "failure-incorrect-record-export",
"test": VerifyHardwareFlowTrackerStatus,
"eos_data": [
{
"trackers": {
"FLOW-TRACKER": {
"active": True,
"inactiveTimeout": 60000,
"activeInterval": 300000,
"exporters": {"CV-TELEMETRY": {"localIntf": "Loopback0", "templateInterval": 3600000}},
}
},
"running": True,
},
{
"trackers": {
"HARDWARE-TRACKER": {
"active": True,
"inactiveTimeout": 6000,
"activeInterval": 30000,
"exporters": {"CVP-TELEMETRY": {"localIntf": "Loopback10", "templateInterval": 3600000}},
}
},
"running": True,
},
],
"inputs": {
"trackers": [
{
"name": "FLOW-TRACKER",
"record_export": {"on_inactive_timeout": 6000, "on_interval": 30000},
},
{
"name": "HARDWARE-TRACKER",
"record_export": {"on_inactive_timeout": 60000, "on_interval": 300000},
},
]
},
"expected": {
"result": "failure",
"messages": [
"FLOW-TRACKER: \n"
"Expected `6000` as the inactive timeout, but found `60000` instead.\nExpected `30000` as the interval, but found `300000` instead.\n",
"HARDWARE-TRACKER: \n"
"Expected `60000` as the inactive timeout, but found `6000` instead.\nExpected `300000` as the interval, but found `30000` instead.\n",
],
},
},
{
"name": "failure-incorrect-exporters",
"test": VerifyHardwareFlowTrackerStatus,
"eos_data": [
{
"trackers": {
"FLOW-TRACKER": {
"active": True,
"inactiveTimeout": 60000,
"activeInterval": 300000,
"exporters": {
"CV-TELEMETRY": {"localIntf": "Loopback0", "templateInterval": 3600000},
"CVP-FLOW": {"localIntf": "Loopback0", "templateInterval": 3600000},
},
}
},
"running": True,
},
{
"trackers": {
"HARDWARE-TRACKER": {
"active": True,
"inactiveTimeout": 6000,
"activeInterval": 30000,
"exporters": {
"CVP-TELEMETRY": {"localIntf": "Loopback10", "templateInterval": 3600000},
"Hardware-flow": {"localIntf": "Loopback10", "templateInterval": 3600000},
},
}
},
"running": True,
},
],
"inputs": {
"trackers": [
{
"name": "FLOW-TRACKER",
"exporters": [
{"name": "CV-TELEMETRY", "local_interface": "Loopback0", "template_interval": 3600000},
{"name": "CVP-FLOW", "local_interface": "Loopback10", "template_interval": 3500000},
],
},
{
"name": "HARDWARE-TRACKER",
"exporters": [
{"name": "Hardware-flow", "local_interface": "Loopback99", "template_interval": 3000000},
{"name": "Reverse-flow", "local_interface": "Loopback101", "template_interval": 3000000},
],
},
]
},
"expected": {
"result": "failure",
"messages": [
"FLOW-TRACKER: \n"
"Exporter `CVP-FLOW`: \n"
"Expected `Loopback10` as the local interface, but found `Loopback0` instead.\n"
"Expected `3500000` as the template interval, but found `3600000` instead.\n",
"HARDWARE-TRACKER: \n"
"Exporter `Hardware-flow`: \n"
"Expected `Loopback99` as the local interface, but found `Loopback10` instead.\n"
"Expected `3000000` as the template interval, but found `3600000` instead.\n"
"Exporter `Reverse-flow` is not configured.\n",
],
},
},
{
"name": "failure-all-type",
"test": VerifyHardwareFlowTrackerStatus,
"eos_data": [
{
"trackers": {
"HARDWARE-TRACKER": {
"active": True,
"inactiveTimeout": 60000,
"activeInterval": 300000,
"exporters": {"CVP-TELEMETRY": {"localIntf": "Loopback10", "templateInterval": 3600000}},
}
},
"running": True,
},
{
"trackers": {
"FLOW-TRIGGER": {
"active": False,
"inactiveTimeout": 60000,
"activeInterval": 300000,
"exporters": {"CV-TELEMETRY": {"localIntf": "Loopback0", "templateInterval": 3600000}},
}
},
"running": True,
},
{
"trackers": {
"HARDWARE-FLOW": {
"active": True,
"inactiveTimeout": 6000,
"activeInterval": 30000,
"exporters": {"CVP-TELEMETRY": {"localIntf": "Loopback10", "templateInterval": 3600000}},
}
},
"running": True,
},
{
"trackers": {
"FLOW-TRACKER2": {
"active": True,
"inactiveTimeout": 60000,
"activeInterval": 300000,
"exporters": {
"CV-TELEMETRY": {"localIntf": "Loopback0", "templateInterval": 3600000},
"CVP-FLOW": {"localIntf": "Loopback0", "templateInterval": 3600000},
},
}
},
"running": True,
},
{
"trackers": {
"HARDWARE-TRACKER2": {
"active": True,
"inactiveTimeout": 6000,
"activeInterval": 30000,
"exporters": {
"CVP-TELEMETRY": {"localIntf": "Loopback10", "templateInterval": 3600000},
"Hardware-flow": {"localIntf": "Loopback10", "templateInterval": 3600000},
},
}
},
"running": True,
},
],
"inputs": {
"trackers": [
{"name": "FLOW-Sample"},
{
"name": "FLOW-TRIGGER",
"record_export": {"on_inactive_timeout": 60000, "on_interval": 300000},
"exporters": [{"name": "CV-TELEMETRY", "local_interface": "Loopback0", "template_interval": 3600000}],
},
{
"name": "HARDWARE-FLOW",
"record_export": {"on_inactive_timeout": 60000, "on_interval": 300000},
},
{
"name": "FLOW-TRACKER2",
"exporters": [
{"name": "CV-TELEMETRY", "local_interface": "Loopback0", "template_interval": 3600000},
{"name": "CVP-FLOW", "local_interface": "Loopback10", "template_interval": 3500000},
],
},
{
"name": "HARDWARE-TRACKER2",
"exporters": [
{"name": "Hardware-flow", "local_interface": "Loopback99", "template_interval": 3000000},
{"name": "Reverse-flow", "local_interface": "Loopback101", "template_interval": 3000000},
],
},
]
},
"expected": {
"result": "failure",
"messages": [
"Hardware flow tracker `FLOW-Sample` is not configured.",
"Hardware flow tracker `FLOW-TRIGGER` is not active.",
"HARDWARE-FLOW: \n"
"Expected `60000` as the inactive timeout, but found `6000` instead.\nExpected `300000` as the interval, but found `30000` instead.\n",
"FLOW-TRACKER2: \nExporter `CVP-FLOW`: \n"
"Expected `Loopback10` as the local interface, but found `Loopback0` instead.\n"
"Expected `3500000` as the template interval, but found `3600000` instead.\n",
"HARDWARE-TRACKER2: \nExporter `Hardware-flow`: \n"
"Expected `Loopback99` as the local interface, but found `Loopback10` instead.\n"
"Expected `3000000` as the template interval, but found `3600000` instead.\n"
"Exporter `Reverse-flow` is not configured.\n",
],
},
},
]