frr/tests/topotests/bfd_vrflite_topo1/test_bfd_vrflite_topo1.py

Ignoring revisions in .git-blame-ignore-revs. Click here to bypass and see the normal blame view.

140 lines
4.2 KiB
Python
Raw Normal View History

#!/usr/bin/env python
# SPDX-License-Identifier: ISC
#
# test_bfd_vrflite_topo1.py
# Part of NetDEF Topology Tests
#
# Copyright (c) 2018 by
# Network Device Education Foundation, Inc. ("NetDEF")
# Copyright (c) 2022 by 6WIND
#
"""
test_bfd_vrflite_topo1.py: Test the FRR BFD daemon.
"""
import os
import sys
import json
from functools import partial
import pytest
# Save the Current Working Directory to find configuration files.
CWD = os.path.dirname(os.path.realpath(__file__))
sys.path.append(os.path.join(CWD, "../"))
# pylint: disable=C0413
# Import topogen and topotest helpers
from lib import topotest
from lib.topogen import Topogen, TopoRouter, get_topogen
from lib.topolog import logger
# Required to instantiate the topology builder class.
pytestmark = [pytest.mark.bfdd, pytest.mark.bgpd]
def build_topo(tgen):
# Create 2 routers
for routern in range(1, 3):
tgen.add_router("r{}".format(routern))
switch = tgen.add_switch("s1")
switch.add_link(tgen.gears["r1"])
switch.add_link(tgen.gears["r2"])
switch = tgen.add_switch("s2")
switch.add_link(tgen.gears["r2"])
switch = tgen.add_switch("s3")
switch.add_link(tgen.gears["r1"])
def setup_module(mod):
"Sets up the pytest environment"
tgen = Topogen(build_topo, mod.__name__)
tgen.start_topology()
router_list = tgen.routers()
logger.info("Testing with Linux VRF support and udp_l3mdev=0")
if os.system("echo 0 > /proc/sys/net/ipv4/udp_l3mdev_accept") != 0:
return pytest.skip(
"Skipping BFD vrflite Topo1 Test. Linux VRF not available on System"
)
for rname, router in router_list.items():
router.net.add_l3vrf("vrf1", 10)
router.net.add_l3vrf("vrf2", 20)
router.net.add_l3vrf("vrf3", 30)
router.net.add_vlan(rname + "-eth0.100", rname + "-eth0", 100)
router.net.add_vlan(rname + "-eth0.200", rname + "-eth0", 200)
router.net.add_vlan(rname + "-eth0.300", rname + "-eth0", 300)
router.net.attach_iface_to_l3vrf(rname + "-eth0.100", "vrf1")
router.net.attach_iface_to_l3vrf(rname + "-eth0.200", "vrf2")
router.net.add_loop(rname + "-loop1")
router.net.add_loop(rname + "-loop2")
router.net.attach_iface_to_l3vrf(rname + "-loop1", "vrf1")
router.net.attach_iface_to_l3vrf(rname + "-loop2", "vrf2")
router.net.attach_iface_to_l3vrf(rname + "-eth0", "vrf3")
for rname, router in router_list.items():
router.load_config(
TopoRouter.RD_ZEBRA, os.path.join(CWD, "{}/zebra.conf".format(rname))
)
router.load_config(
TopoRouter.RD_BFD, os.path.join(CWD, "{}/bfdd.conf".format(rname))
)
# Initialize all routers.
tgen.start_router()
def teardown_module(_mod):
"Teardown the pytest environment"
tgen = get_topogen()
# Move interfaces out of vrf namespace and delete the namespace
router_list = tgen.routers()
for rname, router in router_list.items():
router.net.del_iface(rname + "-eth0.100")
router.net.del_iface(rname + "-eth0.200")
router.net.del_iface(rname + "-eth0.300")
router.net.del_iface(rname + "-loop1")
router.net.del_iface(rname + "-loop2")
tgen.stop_topology()
def test_bfd_connection():
"Assert that the BFD peers can find themselves."
tgen = get_topogen()
if tgen.routers_have_failure():
pytest.skip(tgen.errors)
logger.info("waiting for bfd peers to go up")
router = tgen.gears["r1"]
json_file = "{}/{}/bfd_peers_status.json".format(CWD, "r1")
expected = json.loads(open(json_file).read())
test_func = partial(
topotest.router_json_cmp, router, "show bfd peers json", expected
)
_, result = topotest.run_and_expect(test_func, None, count=16, wait=1)
assertmsg = '"{}" JSON output mismatches'.format(router.name)
assert result is None, assertmsg
def test_memory_leak():
"Run the memory leak test and report results."
tgen = get_topogen()
if not tgen.is_memleak_enabled():
pytest.skip("Memory leak test/report is disabled")
tgen.report_memory_leaks()
if __name__ == "__main__":
args = ["-s"] + sys.argv[1:]
sys.exit(pytest.main(args))