1
0
Fork 0
telegraf/plugins/inputs/modbus/testcases/metric_style_issue_16031/telegraf.conf

16 lines
519 B
Text
Raw Permalink Normal View History

[[inputs.modbus]]
name_override = "modbus"
name = "modbus"
timeout = "1s"
controller = "tcp://172.16.2.31:502"
configuration_type = "metric"
exclude_register_type_tag = true
[[inputs.modbus.metric]]
slave_id = 1
byte_order = "ABCD"
fields = [
{register = "holding", address = 101, name = '4x0102:INT', type = 'INT16'},
{register = "holding", address = 102, name = '4x0103:INT', type = 'INT16'},
{register = "input", address = 134, name = '3x0135:INT', type = 'INT16'},
]