# Multifile Input Plugin
|
||
|
|
||
|
This plugin reads the combined data from multiple files into a single metric,
|
||
|
creating one field or tag per file. This is often useful creating custom
|
||
|
metrics from the `/sys` or `/proc` filesystems.
|
||
|
|
||
|
> [!NOTE]
|
||
|
> To parse metrics from a single file you should use the [file][file_plugin]
|
||
|
> input plugin instead.
|
||
|
|
||
|
⭐ Telegraf v1.10.0
|
||
|
🏷️ system
|
||
|
💻 all
|
||
|
|
||
|
[file_plugin]: /plugins/inputs/file/README.md
|
||
|
|
||
|
## Global configuration options <!-- @/docs/includes/plugin_config.md -->
|
||
|
|
||
|
In addition to the plugin-specific configuration settings, plugins support
|
||
|
additional global and plugin configuration settings. These settings are used to
|
||
|
modify metrics, tags, and field or create aliases and configure ordering, etc.
|
||
|
See the [CONFIGURATION.md][CONFIGURATION.md] for more details.
|
||
|
|
||
|
[CONFIGURATION.md]: ../../../docs/CONFIGURATION.md#plugins
|
||
|
|
||
|
## Configuration
|
||
|
|
||
|
```toml @sample.conf
|
||
|
# Aggregates the contents of multiple files into a single point
|
||
|
[[inputs.multifile]]
|
||
|
## Base directory where telegraf will look for files.
|
||
|
## Omit this option to use absolute paths.
|
||
|
base_dir = "/sys/bus/i2c/devices/1-0076/iio:device0"
|
||
|
|
||
|
## If true discard all data when a single file can't be read.
|
||
|
## Else, Telegraf omits the field generated from this file.
|
||
|
# fail_early = true
|
||
|
|
||
|
## Files to parse each interval.
|
||
|
[[inputs.multifile.file]]
|
||
|
file = "in_pressure_input"
|
||
|
dest = "pressure"
|
||
|
conversion = "float"
|
||
|
[[inputs.multifile.file]]
|
||
|
file = "in_temp_input"
|
||
|
dest = "temperature"
|
||
|
conversion = "float(3)"
|
||
|
[[inputs.multifile.file]]
|
||
|
file = "in_humidityrelative_input"
|
||
|
dest = "humidityrelative"
|
||
|
conversion = "float(3)"
|
||
|
```
|
||
|
|
||
|
## Metrics
|
||
|
|
||
|
Each file table can contain the following options:
|
||
|
|
||
|
* `file`:
|
||
|
Path of the file to be parsed, relative to the `base_dir`.
|
||
|
* `dest`:
|
||
|
Name of the field/tag key, defaults to `$(basename file)`.
|
||
|
* `conversion`:
|
||
|
Data format used to parse the file contents:
|
||
|
* `float(X)`: Converts the input value into a float and divides by the Xth
|
||
|
power of 10. Effectively just moves the decimal left X places. For example
|
||
|
a value of `123` with `float(2)` will result in `1.23`.
|
||
|
* `float`: Converts the value into a float with no adjustment.
|
||
|
Same as `float(0)`.
|
||
|
* `int`: Converts the value into an integer.
|
||
|
* `string`, `""`: No conversion.
|
||
|
* `bool`: Converts the value into a boolean.
|
||
|
* `tag`: File content is used as a tag.
|
||
|
|
||
|
## Example Output
|
||
|
|
||
|
This example shows a BME280 connected to a Raspberry Pi, using the sample
|
||
|
config.
|
||
|
|
||
|
```text
|
||
|
multifile pressure=101.343285156,temperature=20.4,humidityrelative=48.9 1547202076000000000
|
||
|
```
|
||
|
|
||
|
To reproduce this, connect a BMP280 to the board's GPIO pins and register the
|
||
|
BME280 device driver
|
||
|
|
||
|
```sh
|
||
|
cd /sys/bus/i2c/devices/i2c-1
|
||
|
echo bme280 0x76 > new_device
|
||
|
```
|
||
|
|
||
|
The kernel driver provides the following files in
|
||
|
`/sys/bus/i2c/devices/1-0076/iio:device0`:
|
||
|
|
||
|
* `in_humidityrelative_input`: `48900`
|
||
|
* `in_pressure_input`: `101.343285156`
|
||
|
* `in_temp_input`: `20400`
|