Adding upstream version 1.34.4.
Signed-off-by: Daniel Baumann <daniel@debian.org>
This commit is contained in:
parent
e393c3af3f
commit
4978089aab
4963 changed files with 677545 additions and 0 deletions
51
plugins/inputs/modbus/sample_general_end.conf
Normal file
51
plugins/inputs/modbus/sample_general_end.conf
Normal file
|
@ -0,0 +1,51 @@
|
|||
## RS485 specific settings. Only take effect for serial controllers.
|
||||
## Note: This has to be at the end of the modbus configuration due to
|
||||
## TOML constraints.
|
||||
# [inputs.modbus.rs485]
|
||||
## Delay RTS prior to sending
|
||||
# delay_rts_before_send = "0ms"
|
||||
## Delay RTS after to sending
|
||||
# delay_rts_after_send = "0ms"
|
||||
## Pull RTS line to high during sending
|
||||
# rts_high_during_send = false
|
||||
## Pull RTS line to high after sending
|
||||
# rts_high_after_send = false
|
||||
## Enabling receiving (Rx) during transmission (Tx)
|
||||
# rx_during_tx = false
|
||||
|
||||
## Enable workarounds required by some devices to work correctly
|
||||
# [inputs.modbus.workarounds]
|
||||
## Pause after connect delays the first request by the specified time.
|
||||
## This might be necessary for (slow) devices.
|
||||
# pause_after_connect = "0ms"
|
||||
|
||||
## Pause between read requests sent to the device.
|
||||
## This might be necessary for (slow) serial devices.
|
||||
# pause_between_requests = "0ms"
|
||||
|
||||
## Close the connection after every gather cycle.
|
||||
## Usually the plugin closes the connection after a certain idle-timeout,
|
||||
## however, if you query a device with limited simultaneous connectivity
|
||||
## (e.g. serial devices) from multiple instances you might want to only
|
||||
## stay connected during gather and disconnect afterwards.
|
||||
# close_connection_after_gather = false
|
||||
|
||||
## Force the plugin to read each field in a separate request.
|
||||
## This might be necessary for devices not conforming to the spec,
|
||||
## see https://github.com/influxdata/telegraf/issues/12071.
|
||||
# one_request_per_field = false
|
||||
|
||||
## Enforce the starting address to be zero for the first request on
|
||||
## coil registers. This is necessary for some devices see
|
||||
## https://github.com/influxdata/telegraf/issues/8905
|
||||
# read_coils_starting_at_zero = false
|
||||
|
||||
## String byte-location in registers AFTER byte-order conversion
|
||||
## Some device (e.g. EM340) place the string byte in only the upper or
|
||||
## lower byte location of a register see
|
||||
## https://github.com/influxdata/telegraf/issues/14748
|
||||
## Available settings:
|
||||
## lower -- use only lower byte of the register i.e. 00XX 00XX 00XX 00XX
|
||||
## upper -- use only upper byte of the register i.e. XX00 XX00 XX00 XX00
|
||||
## By default both bytes of the register are used i.e. XXXX XXXX.
|
||||
# string_register_location = ""
|
Loading…
Add table
Add a link
Reference in a new issue