# Redfish Input Plugin
|
||||
|
||||
The `redfish` plugin gathers metrics and status information about CPU
|
||||
temperature, fanspeed, Powersupply, voltage, hostname and Location details
|
||||
(datacenter, placement, rack and room) of hardware servers for which [DMTF's
|
||||
Redfish](https://redfish.dmtf.org/) is enabled.
|
||||
|
||||
Telegraf minimum version: Telegraf 1.15.0
|
||||
|
||||
## Global configuration options <!-- @/docs/includes/plugin_config.md -->
|
||||
|
||||
In addition to the plugin-specific configuration settings, plugins support
|
||||
additional global and plugin configuration settings. These settings are used to
|
||||
modify metrics, tags, and field or create aliases and configure ordering, etc.
|
||||
See the [CONFIGURATION.md][CONFIGURATION.md] for more details.
|
||||
|
||||
[CONFIGURATION.md]: ../../../docs/CONFIGURATION.md#plugins
|
||||
|
||||
## Secret-store support
|
||||
|
||||
This plugin supports secrets from secret-stores for the `username` and
|
||||
`password` options. See the [secret-store documentation][SECRETSTORE] for more
|
||||
details on how to use them.
|
||||
|
||||
[SECRETSTORE]: ../../../docs/CONFIGURATION.md#secret-store-secrets
|
||||
|
||||
## Configuration
|
||||
|
||||
```toml @sample.conf
|
||||
# Read CPU, Fans, Powersupply and Voltage metrics of hardware server through redfish APIs
|
||||
[[inputs.redfish]]
|
||||
## Redfish API Base URL.
|
||||
address = "https://127.0.0.1:5000"
|
||||
|
||||
## Credentials for the Redfish API. Can also use secrets.
|
||||
username = "root"
|
||||
password = "password123456"
|
||||
|
||||
## System Id to collect data for in Redfish APIs.
|
||||
computer_system_id="System.Embedded.1"
|
||||
|
||||
## Metrics to collect
|
||||
## The metric collects to gather. Choose from "power" and "thermal".
|
||||
# include_metrics = ["power", "thermal"]
|
||||
|
||||
## Tag sets allow you to include redfish OData link parent data
|
||||
## For Example.
|
||||
## Thermal data is an OData link with parent Chassis which has a link of Location.
|
||||
## For more info see the Redfish Resource and Schema Guide at DMTFs website.
|
||||
## Available sets are: "chassis.location" and "chassis"
|
||||
# include_tag_sets = ["chassis.location"]
|
||||
|
||||
## Workarounds
|
||||
## Defines workarounds for certain hardware vendors. Choose from:
|
||||
## * ilo4-thermal - Do not pass 0Data-Version header to Thermal endpoint
|
||||
# workarounds = []
|
||||
|
||||
## Amount of time allowed to complete the HTTP request
|
||||
# timeout = "5s"
|
||||
|
||||
## Optional TLS Config
|
||||
# tls_ca = "/etc/telegraf/ca.pem"
|
||||
# tls_cert = "/etc/telegraf/cert.pem"
|
||||
# tls_key = "/etc/telegraf/key.pem"
|
||||
## Use TLS but skip chain & host verification
|
||||
# insecure_skip_verify = false
|
||||
```
|
||||
|
||||
## Metrics
|
||||
|
||||
- redfish_thermal_temperatures
|
||||
- tags:
|
||||
- source
|
||||
- member_id
|
||||
- address
|
||||
- name
|
||||
- state
|
||||
- health
|
||||
- fields:
|
||||
- reading_celsius
|
||||
- upper_threshold_critical
|
||||
- upper_threshold_fatal
|
||||
- lower_threshold_critical
|
||||
- lower_threshold_fatal
|
||||
|
||||
- redfish_thermal_fans
|
||||
- tags:
|
||||
- source
|
||||
- member_id
|
||||
- address
|
||||
- name
|
||||
- state
|
||||
- health
|
||||
- fields:
|
||||
- reading_rpm (or) reading_percent
|
||||
- upper_threshold_critical
|
||||
- upper_threshold_fatal
|
||||
- lower_threshold_critical
|
||||
- lower_threshold_fatal
|
||||
|
||||
- redfish_power_powersupplies
|
||||
- tags:
|
||||
- source
|
||||
- member_id
|
||||
- address
|
||||
- name
|
||||
- state
|
||||
- health
|
||||
- fields:
|
||||
- last_power_output_watts
|
||||
- line_input_voltage
|
||||
- power_capacity_watts
|
||||
- power_input_watts
|
||||
- power_output_watts
|
||||
|
||||
- redfish_power_voltages (available only if voltage data is found)
|
||||
- tags:
|
||||
- source
|
||||
- member_id
|
||||
- address
|
||||
- name
|
||||
- state
|
||||
- health
|
||||
- fields:
|
||||
- reading_volts
|
||||
- upper_threshold_critical
|
||||
- upper_threshold_fatal
|
||||
- lower_threshold_critical
|
||||
- lower_threshold_fatal
|
||||
|
||||
## Tag Sets
|
||||
|
||||
- chassis.location
|
||||
- tags:
|
||||
- datacenter (available only if location data is found)
|
||||
- rack (available only if location data is found)
|
||||
- room (available only if location data is found)
|
||||
- row (available only if location data is found)
|
||||
|
||||
- chassis
|
||||
- tags:
|
||||
- chassis_chassistype
|
||||
- chassis_manufacturer
|
||||
- chassis_model
|
||||
- chassis_partnumber
|
||||
- chassis_powerstate
|
||||
- chassis_sku
|
||||
- chassis_serialnumber
|
||||
- chassis_state
|
||||
- chassis_health
|
||||
|
||||
## Example Output
|
||||
|
||||
```text
|
||||
redfish_thermal_temperatures,address=127.0.0.1,chassis_chassistype=RackMount,chassis_health=OK,chassis_manufacturer=Contoso,chassis_model=3500RX,chassis_partnumber=224071-J23,chassis_powerstate=On,chassis_serialnumber=437XR1138R2,chassis_sku=8675309,chassis_state=Enabled,health=OK,member_id=0,name=CPU1\ Temp,rack=WEB43,row=North,source=web483,state=Enabled reading_celsius=41,upper_threshold_critical=45,upper_threshold_fatal=48 1691270160000000000
|
||||
redfish_thermal_temperatures,address=127.0.0.1,chassis_chassistype=RackMount,chassis_health=OK,chassis_manufacturer=Contoso,chassis_model=3500RX,chassis_partnumber=224071-J23,chassis_powerstate=On,chassis_serialnumber=437XR1138R2,chassis_sku=8675309,chassis_state=Enabled,member_id=1,name=CPU2\ Temp,rack=WEB43,row=North,source=web483,state=Disabled upper_threshold_critical=45,upper_threshold_fatal=48 1691270160000000000
|
||||
redfish_thermal_temperatures,address=127.0.0.1,chassis_chassistype=RackMount,chassis_health=OK,chassis_manufacturer=Contoso,chassis_model=3500RX,chassis_partnumber=224071-J23,chassis_powerstate=On,chassis_serialnumber=437XR1138R2,chassis_sku=8675309,chassis_state=Enabled,health=OK,member_id=2,name=Chassis\ Intake\ Temp,rack=WEB43,row=North,source=web483,state=Enabled upper_threshold_critical=40,upper_threshold_fatal=50,lower_threshold_critical=5,lower_threshold_fatal=0,reading_celsius=25 1691270160000000000
|
||||
redfish_thermal_fans,address=127.0.0.1,chassis_chassistype=RackMount,chassis_health=OK,chassis_manufacturer=Contoso,chassis_model=3500RX,chassis_partnumber=224071-J23,chassis_powerstate=On,chassis_serialnumber=437XR1138R2,chassis_sku=8675309,chassis_state=Enabled,health=OK,member_id=0,name=BaseBoard\ System\ Fan,rack=WEB43,row=North,source=web483,state=Enabled lower_threshold_fatal=0i,reading_rpm=2100i 1691270160000000000
|
||||
redfish_thermal_fans,address=127.0.0.1,chassis_chassistype=RackMount,chassis_health=OK,chassis_manufacturer=Contoso,chassis_model=3500RX,chassis_partnumber=224071-J23,chassis_powerstate=On,chassis_serialnumber=437XR1138R2,chassis_sku=8675309,chassis_state=Enabled,health=OK,member_id=1,name=BaseBoard\ System\ Fan\ Backup,rack=WEB43,row=North,source=web483,state=Enabled lower_threshold_fatal=0i,reading_rpm=2050i 1691270160000000000
|
||||
redfish_power_powersupplies,address=127.0.0.1,chassis_chassistype=RackMount,chassis_health=OK,chassis_manufacturer=Contoso,chassis_model=3500RX,chassis_partnumber=224071-J23,chassis_powerstate=On,chassis_serialnumber=437XR1138R2,chassis_sku=8675309,chassis_state=Enabled,health=Warning,member_id=0,name=Power\ Supply\ Bay,rack=WEB43,row=North,source=web483,state=Enabled line_input_voltage=120,last_power_output_watts=325,power_capacity_watts=800 1691270160000000000
|
||||
redfish_power_voltages,address=127.0.0.1,chassis_chassistype=RackMount,chassis_health=OK,chassis_manufacturer=Contoso,chassis_model=3500RX,chassis_partnumber=224071-J23,chassis_powerstate=On,chassis_serialnumber=437XR1138R2,chassis_sku=8675309,chassis_state=Enabled,health=OK,member_id=0,name=VRM1\ Voltage,rack=WEB43,row=North,source=web483,state=Enabled upper_threshold_fatal=15,lower_threshold_critical=11,lower_threshold_fatal=10,reading_volts=12,upper_threshold_critical=13 1691270160000000000
|
||||
redfish_power_voltages,address=127.0.0.1,chassis_chassistype=RackMount,chassis_health=OK,chassis_manufacturer=Contoso,chassis_model=3500RX,chassis_partnumber=224071-J23,chassis_powerstate=On,chassis_serialnumber=437XR1138R2,chassis_sku=8675309,chassis_state=Enabled,health=OK,member_id=1,name=VRM2\ Voltage,rack=WEB43,row=North,source=web483,state=Enabled reading_volts=5,upper_threshold_critical=7,lower_threshold_critical=4.5 1691270160000000000
|
||||
redfish_thermal_temperatures,address=127.0.0.1,chassis_chassistype=RackMount,chassis_health=OK,chassis_manufacturer=Contoso,chassis_model=3500RX,chassis_partnumber=224071-J23,chassis_powerstate=On,chassis_serialnumber=437XR1138R2,chassis_sku=8675309,chassis_state=Enabled,health=OK,member_id=0,name=CPU1\ Temp,rack=WEB43,row=North,source=web483,state=Enabled upper_threshold_critical=45,upper_threshold_fatal=48,reading_celsius=41 1691270170000000000
|
||||
redfish_thermal_temperatures,address=127.0.0.1,chassis_chassistype=RackMount,chassis_health=OK,chassis_manufacturer=Contoso,chassis_model=3500RX,chassis_partnumber=224071-J23,chassis_powerstate=On,chassis_serialnumber=437XR1138R2,chassis_sku=8675309,chassis_state=Enabled,member_id=1,name=CPU2\ Temp,rack=WEB43,row=North,source=web483,state=Disabled upper_threshold_critical=45,upper_threshold_fatal=48 1691270170000000000
|
||||
redfish_thermal_temperatures,address=127.0.0.1,chassis_chassistype=RackMount,chassis_health=OK,chassis_manufacturer=Contoso,chassis_model=3500RX,chassis_partnumber=224071-J23,chassis_powerstate=On,chassis_serialnumber=437XR1138R2,chassis_sku=8675309,chassis_state=Enabled,health=OK,member_id=2,name=Chassis\ Intake\ Temp,rack=WEB43,row=North,source=web483,state=Enabled lower_threshold_critical=5,lower_threshold_fatal=0,reading_celsius=25,upper_threshold_critical=40,upper_threshold_fatal=50 1691270170000000000
|
||||
```
|
Loading…
Add table
Add a link
Reference in a new issue