# Intel Baseband Accelerator Input Plugin collects metrics from both dedicated and integrated
|
|
# Intel devices that provide Wireless Baseband hardware acceleration.
|
|
# This plugin ONLY supports Linux.
|
|
[[inputs.intel_baseband]]
|
|
## Path to socket exposed by pf-bb-config for CLI interaction (mandatory).
|
|
## In version v23.03 of pf-bb-config the path is created according to the schema:
|
|
## "/tmp/pf_bb_config.0000\:<b>\:<d>.<f>.sock" where 0000\:<b>\:<d>.<f> is the PCI device ID.
|
|
socket_path = ""
|
|
|
|
## Path to log file exposed by pf-bb-config with telemetry to read (mandatory).
|
|
## In version v23.03 of pf-bb-config the path is created according to the schema:
|
|
## "/var/log/pf_bb_cfg_0000\:<b>\:<d>.<f>.log" where 0000\:<b>\:<d>.<f> is the PCI device ID.
|
|
log_file_path = ""
|
|
|
|
## Specifies plugin behavior regarding unreachable socket (which might not have been initialized yet).
|
|
## Available choices:
|
|
## - error: Telegraf will return an error on startup if socket is unreachable
|
|
## - ignore: Telegraf will ignore error regarding unreachable socket on both startup and gather
|
|
# unreachable_socket_behavior = "error"
|
|
|
|
## Duration that defines how long the connected socket client will wait for
|
|
## a response before terminating connection.
|
|
## Since it's local socket access to a fast packet processing application, the timeout should
|
|
## be sufficient for most users.
|
|
## Setting the value to 0 disables the timeout (not recommended).
|
|
# socket_access_timeout = "1s"
|
|
|
|
## Duration that defines maximum time plugin will wait for pf-bb-config to write telemetry to the log file.
|
|
## Timeout may differ depending on the environment.
|
|
## Must be equal or larger than 50ms.
|
|
# wait_for_telemetry_timeout = "1s"
|