## RS485 specific settings. Only take effect for serial controllers.
## Note: This has to be at the end of the modbus configuration due to
## TOML constraints.
# [inputs.modbus.rs485]
## Delay RTS prior to sending
# delay_rts_before_send = "0ms"
## Delay RTS after to sending
# delay_rts_after_send = "0ms"
## Pull RTS line to high during sending
# rts_high_during_send = false
## Pull RTS line to high after sending
# rts_high_after_send = false
## Enabling receiving (Rx) during transmission (Tx)
# rx_during_tx = false
## Enable workarounds required by some devices to work correctly
# [inputs.modbus.workarounds]
## Pause after connect delays the first request by the specified time.
## This might be necessary for (slow) devices.
# pause_after_connect = "0ms"
## Pause between read requests sent to the device.
## This might be necessary for (slow) serial devices.
# pause_between_requests = "0ms"
## Close the connection after every gather cycle.
## Usually the plugin closes the connection after a certain idle-timeout,
## however, if you query a device with limited simultaneous connectivity
## (e.g. serial devices) from multiple instances you might want to only
## stay connected during gather and disconnect afterwards.
# close_connection_after_gather = false
## Force the plugin to read each field in a separate request.
## This might be necessary for devices not conforming to the spec,
## see https://github.com/influxdata/telegraf/issues/12071.
# one_request_per_field = false
## Enforce the starting address to be zero for the first request on
## coil registers. This is necessary for some devices see
## https://github.com/influxdata/telegraf/issues/8905
# read_coils_starting_at_zero = false
## String byte-location in registers AFTER byte-order conversion
## Some device (e.g. EM340) place the string byte in only the upper or
## lower byte location of a register see
## https://github.com/influxdata/telegraf/issues/14748
## Available settings:
## lower -- use only lower byte of the register i.e. 00XX 00XX 00XX 00XX
## upper -- use only upper byte of the register i.e. XX00 XX00 XX00 XX00
## By default both bytes of the register are used i.e. XXXX XXXX.
# string_register_location = ""