.TH RAID6CHECK 8 "" v1.0.0
|
||
|
.SH NAME
|
||
|
raid6check \- check MD RAID6 device for errors
|
||
|
.I aka
|
||
|
Linux Software RAID
|
||
|
|
||
|
.SH SYNOPSIS
|
||
|
|
||
|
.BI raid6check " <raid6 device> <start stripe> <number of stripes>"
|
||
|
|
||
|
.SH DESCRIPTION
|
||
|
RAID6 devices in which one single component drive has errors can use
|
||
|
the double parity in order to find out which component drive.
|
||
|
The "raid6check" tool checks, for each stripe, the double parity
|
||
|
consistency, reports mismatches and, if possible, which
|
||
|
component drive has the mismatch.
|
||
|
Since it works at stripe level, it can report different drives with
|
||
|
mismatches at different stripes.
|
||
|
|
||
|
"raid6check" requires a non-degraded RAID6 MD device as first
|
||
|
parameter, a starting stripe (usually 0) and the number of stripes
|
||
|
to be checked.
|
||
|
If this third parameter is also 0, it will check the array up to
|
||
|
the end.
|
||
|
|
||
|
"raid6check" will start printing information about the RAID6, then
|
||
|
for each stripe, it will report the parity rotation status.
|
||
|
In case of parity mismatches, "raid6check" reports, if possible,
|
||
|
which component drive could be responsible. Otherwise it reports
|
||
|
that it is not possible to find the component drive.
|
||
|
|
||
|
If the given MD device is not a RAID6, "raid6check" will, of
|
||
|
course, not continue.
|
||
|
|
||
|
If the RAID6 MD device is degraded, "raid6check" will report
|
||
|
an error and it will not proceed further.
|
||
|
|
||
|
No write operations are performed on the array or the components.
|
||
|
Furthermore, the checked array can be online and in use during
|
||
|
the operation of "raid6check".
|
||
|
|
||
|
.SH EXAMPLES
|
||
|
|
||
|
.B " raid6check /dev/md0 0 0"
|
||
|
.br
|
||
|
This will check /dev/md0 from start to end.
|
||
|
|
||
|
.B " raid6check /dev/md3 0 1"
|
||
|
.br
|
||
|
This will check the first stripe of /dev/md3.
|
||
|
|
||
|
.B " raid6check /dev/md1 1000 0"
|
||
|
.br
|
||
|
This will check /dev/md1 from stripe 1000 up to the end.
|
||
|
|
||
|
.B " raid6check /dev/m127 128 256"
|
||
|
.br
|
||
|
This will check 256 stripes of /dev/md127 starting from stripe 128.
|
||
|
|
||
|
.B " raid6check /dev/md0 0 0 | grep -i error > md0_err.log"
|
||
|
.br
|
||
|
This will check /dev/md0 completely and create a log file only
|
||
|
with errors, if any.
|
||
|
|
||
|
.SH FILES
|
||
|
|
||
|
"raid6check" uses directly the component drives as found in /dev.
|
||
|
Furthermore, the sysfs interface is needed in order to find out
|
||
|
the RAID6 parameters.
|
||
|
|
||
|
.SH BUGS
|
||
|
Negative parameters can lead to unexpected results.
|
||
|
|
||
|
It is not clear what will happen if the RAID6 MD device gets
|
||
|
degraded during the check.
|
||
|
|
||
|
.PP
|
||
|
The latest version of
|
||
|
.I raid6check
|
||
|
should always be available from
|
||
|
.IP
|
||
|
.B https://www.kernel.org/pub/linux/utils/raid/mdadm/
|
||
|
.PP
|
||
|
Related man pages:
|
||
|
.PP
|
||
|
.IR mdadm (8)
|
||
|
.IR mdmon (8),
|
||
|
.IR mdadm.conf (5),
|
||
|
.IR md (4).
|