29 lines
781 B
Text
29 lines
781 B
Text
. tests/env-imsm-template
|
|
|
|
# RAID 0 and RAID 5 volumes (3 disks) migrate to RAID 5 and RAID 5 volumes (4 disks)
|
|
# NEGATIVE test - migration is not allowed if there is more then one array in a container
|
|
|
|
num_disks=3
|
|
device_list="$dev0 $dev1 $dev2"
|
|
spare_list="$dev3"
|
|
|
|
# Before: RAID 0 volume, 3 disks, 64k chunk size, as member #0
|
|
vol0_level=0
|
|
vol0_comp_size=$((5 * 1024))
|
|
vol0_chunk=64
|
|
vol0_num_comps=$num_disks
|
|
vol0_offset=0
|
|
|
|
# Extra: RAID 5 volume, 3 disks, 64k chunk size, as member #1
|
|
vol1_level=5
|
|
vol1_comp_size=$((5 * 1024))
|
|
vol1_chunk=64
|
|
vol1_num_comps=$((num_disks - 1))
|
|
vol1_offset=$((vol0_comp_size + 4096))
|
|
|
|
# After: RAID 5 volume, 4 disks, 64k chunk size (only member #0)
|
|
vol0_new_level=5
|
|
vol0_new_num_comps=$num_disks
|
|
vol0_new_chunk=64
|
|
|
|
. tests/imsm-grow-template 1 1
|