nvme-wdc-purge-monitor(1)
|
||
|
=========================
|
||
|
|
||
|
NAME
|
||
|
----
|
||
|
nvme-wdc-purge-monitor - Send NVMe WDC Purge-Monitor Vendor Unique Command, return result
|
||
|
|
||
|
SYNOPSIS
|
||
|
--------
|
||
|
[verse]
|
||
|
'nvme wdc purge-monitor' <device>
|
||
|
|
||
|
DESCRIPTION
|
||
|
-----------
|
||
|
For the NVMe device given, send a Vendor Unique WDC Purge-Monitor command and
|
||
|
provide the status of the purge command.
|
||
|
|
||
|
Expected status and description :-
|
||
|
|
||
|
[cols="2*", options="header"]
|
||
|
|===
|
||
|
|Status Code |Description
|
||
|
|
||
|
|0x00
|
||
|
|Purge State Idle.
|
||
|
|
||
|
|0x01
|
||
|
|Purge State Done.
|
||
|
|
||
|
|0x02
|
||
|
|Purge State Busy.
|
||
|
|
||
|
|0x03
|
||
|
|Purge State Error : Purge operation resulted in error, power cycle required.
|
||
|
|
||
|
|0x04
|
||
|
|Purge State Error : Purge operation interrupted by power cycle or reset.
|
||
|
|===
|
||
|
|
||
|
|
||
|
The <device> parameter is mandatory and may be either the NVMe character
|
||
|
device (ex: /dev/nvme0), or a namespace block device (ex: /dev/nvme0n1).
|
||
|
|
||
|
This will only work on WDC devices supporting this feature.
|
||
|
Results for any other device are undefined.
|
||
|
|
||
|
On success it returns 0, error code otherwise.
|
||
|
|
||
|
OPTIONS
|
||
|
-------
|
||
|
No options yet.
|
||
|
|
||
|
EXAMPLES
|
||
|
--------
|
||
|
* Has the program issue WDC Purge-Monitor Vendor Unique Command :
|
||
|
+
|
||
|
------------
|
||
|
# nvme wdc purge-monitor /dev/nvme0
|
||
|
------------
|
||
|
|
||
|
NVME
|
||
|
----
|
||
|