.TH "libnvme" 9 "struct nvme_smart_log" "April 2022" "API Manual" LINUX
|
||||
.SH NAME
|
||||
struct nvme_smart_log \- SMART / Health Information Log (Log Identifier 02h)
|
||||
.SH SYNOPSIS
|
||||
struct nvme_smart_log {
|
||||
.br
|
||||
.BI " __u8 critical_warning;"
|
||||
.br
|
||||
.BI " __u8 temperature[2];"
|
||||
.br
|
||||
.BI " __u8 avail_spare;"
|
||||
.br
|
||||
.BI " __u8 spare_thresh;"
|
||||
.br
|
||||
.BI " __u8 percent_used;"
|
||||
.br
|
||||
.BI " __u8 endu_grp_crit_warn_sumry;"
|
||||
.br
|
||||
.BI " __u8 rsvd7[25];"
|
||||
.br
|
||||
.BI " __u8 data_units_read[16];"
|
||||
.br
|
||||
.BI " __u8 data_units_written[16];"
|
||||
.br
|
||||
.BI " __u8 host_reads[16];"
|
||||
.br
|
||||
.BI " __u8 host_writes[16];"
|
||||
.br
|
||||
.BI " __u8 ctrl_busy_time[16];"
|
||||
.br
|
||||
.BI " __u8 power_cycles[16];"
|
||||
.br
|
||||
.BI " __u8 power_on_hours[16];"
|
||||
.br
|
||||
.BI " __u8 unsafe_shutdowns[16];"
|
||||
.br
|
||||
.BI " __u8 media_errors[16];"
|
||||
.br
|
||||
.BI " __u8 num_err_log_entries[16];"
|
||||
.br
|
||||
.BI " __le32 warning_temp_time;"
|
||||
.br
|
||||
.BI " __le32 critical_comp_time;"
|
||||
.br
|
||||
.BI " __le16 temp_sensor[8];"
|
||||
.br
|
||||
.BI " __le32 thm_temp1_trans_count;"
|
||||
.br
|
||||
.BI " __le32 thm_temp2_trans_count;"
|
||||
.br
|
||||
.BI " __le32 thm_temp1_total_time;"
|
||||
.br
|
||||
.BI " __le32 thm_temp2_total_time;"
|
||||
.br
|
||||
.BI " __u8 rsvd232[280];"
|
||||
.br
|
||||
.BI "
|
||||
};
|
||||
.br
|
||||
|
||||
.SH Members
|
||||
.IP "critical_warning" 12
|
||||
This field indicates critical warnings for the state
|
||||
of the controller. Critical warnings may result in an
|
||||
asynchronous event notification to the host. Bits in
|
||||
this field represent the current associated state and
|
||||
are not persistent (see \fIenum nvme_smart_crit\fP).
|
||||
.IP "temperature" 12
|
||||
Composite Temperature: Contains a value corresponding
|
||||
to a temperature in Kelvins that represents the current
|
||||
composite temperature of the controller and namespace(s)
|
||||
associated with that controller. The manner in which
|
||||
this value is computed is implementation specific and
|
||||
may not represent the actual temperature of any physical
|
||||
point in the NVM subsystem. Warning and critical
|
||||
overheating composite temperature threshold values are
|
||||
reported by the WCTEMP and CCTEMP fields in the Identify
|
||||
Controller data structure.
|
||||
.IP "avail_spare" 12
|
||||
Available Spare: Contains a normalized percentage (0%
|
||||
to 100%) of the remaining spare capacity available.
|
||||
.IP "spare_thresh" 12
|
||||
Available Spare Threshold: When the Available Spare
|
||||
falls below the threshold indicated in this field, an
|
||||
asynchronous event completion may occur. The value is
|
||||
indicated as a normalized percentage (0% to 100%).
|
||||
The values 101 to 255 are reserved.
|
||||
.IP "percent_used" 12
|
||||
Percentage Used: Contains a vendor specific estimate
|
||||
of the percentage of NVM subsystem life used based on
|
||||
the actual usage and the manufacturer's prediction of
|
||||
NVM life. A value of 100 indicates that the estimated
|
||||
endurance of the NVM in the NVM subsystem has been
|
||||
consumed, but may not indicate an NVM subsystem failure.
|
||||
The value is allowed to exceed 100. Percentages greater
|
||||
than 254 shall be represented as 255. This value shall
|
||||
be updated once per power-on hour (when the controller
|
||||
is not in a sleep state).
|
||||
.IP "endu_grp_crit_warn_sumry" 12
|
||||
Endurance Group Critical Warning Summary: This field
|
||||
indicates critical warnings for the state of Endurance
|
||||
Groups. Bits in this field represent the current associated
|
||||
state and are not persistent (see \fIenum nvme_smart_egcw\fP).
|
||||
.IP "rsvd7" 12
|
||||
Reserved
|
||||
.IP "data_units_read" 12
|
||||
Data Units Read: Contains the number of 512 byte data
|
||||
units the host has read from the controller; this value
|
||||
does not include metadata. This value is reported in
|
||||
thousands (i.e., a value of 1 corresponds to 1000
|
||||
units of 512 bytes read) and is rounded up (e.g., one
|
||||
indicates the that number of 512 byte data units read
|
||||
is from 1 to 1000, three indicates that the number of
|
||||
512 byte data units read is from 2001 to 3000). When
|
||||
the LBA size is a value other than 512 bytes, the
|
||||
controller shall convert the amount of data read to
|
||||
512 byte units. For the NVM command set, logical blocks
|
||||
read as part of Compare, Read, and Verify operations
|
||||
shall be included in this value. A value of 0h in
|
||||
this field indicates that the number of Data Units Read
|
||||
is not reported.
|
||||
.IP "data_units_written" 12
|
||||
Data Units Written: Contains the number of 512 byte
|
||||
data units the host has written to the controller;
|
||||
this value does not include metadata. This value is
|
||||
reported in thousands (i.e., a value of 1 corresponds
|
||||
to 1000 units of 512 bytes written) and is rounded up
|
||||
(e.g., one indicates that the number of 512 byte data
|
||||
units written is from 1 to 1,000, three indicates that
|
||||
the number of 512 byte data units written is from 2001
|
||||
to 3000). When the LBA size is a value other than 512
|
||||
bytes, the controller shall convert the amount of data
|
||||
written to 512 byte units. For the NVM command set,
|
||||
logical blocks written as part of Write operations shall
|
||||
be included in this value. Write Uncorrectable commands
|
||||
and Write Zeroes commands shall not impact this value.
|
||||
A value of 0h in this field indicates that the number
|
||||
of Data Units Written is not reported.
|
||||
.IP "host_reads" 12
|
||||
Host Read Commands: Contains the number of read commands
|
||||
completed by the controller. For the NVM command set,
|
||||
this value is the sum of the number of Compare commands
|
||||
and the number of Read commands.
|
||||
.IP "host_writes" 12
|
||||
Host Write Commands: Contains the number of write
|
||||
commands completed by the controller. For the NVM
|
||||
command set, this is the number of Write commands.
|
||||
.IP "ctrl_busy_time" 12
|
||||
Controller Busy Time: Contains the amount of time the
|
||||
controller is busy with I/O commands. The controller
|
||||
is busy when there is a command outstanding to an I/O
|
||||
Queue (specifically, a command was issued via an I/O
|
||||
Submission Queue Tail doorbell write and the corresponding
|
||||
completion queue entry has not been posted yet to the
|
||||
associated I/O Completion Queue). This value is
|
||||
reported in minutes.
|
||||
.IP "power_cycles" 12
|
||||
Power Cycles: Contains the number of power cycles.
|
||||
.IP "power_on_hours" 12
|
||||
Power On Hours: Contains the number of power-on hours.
|
||||
This may not include time that the controller was
|
||||
powered and in a non-operational power state.
|
||||
.IP "unsafe_shutdowns" 12
|
||||
Unsafe Shutdowns: Contains the number of unsafe
|
||||
shutdowns. This count is incremented when a Shutdown
|
||||
Notification (CC.SHN) is not received prior to loss of power.
|
||||
.IP "media_errors" 12
|
||||
Media and Data Integrity Errors: Contains the number
|
||||
of occurrences where the controller detected an
|
||||
unrecovered data integrity error. Errors such as
|
||||
uncorrectable ECC, CRC checksum failure, or LBA tag
|
||||
mismatch are included in this field. Errors introduced
|
||||
as a result of a Write Uncorrectable command may or
|
||||
may not be included in this field.
|
||||
.IP "num_err_log_entries" 12
|
||||
Number of Error Information Log Entries: Contains the
|
||||
number of Error Information log entries over the life
|
||||
of the controller.
|
||||
.IP "warning_temp_time" 12
|
||||
Warning Composite Temperature Time: Contains the amount
|
||||
of time in minutes that the controller is operational
|
||||
and the Composite Temperature is greater than or equal
|
||||
to the Warning Composite Temperature Threshold (WCTEMP)
|
||||
field and less than the Critical Composite Temperature
|
||||
Threshold (CCTEMP) field in the Identify Controller
|
||||
data structure. If the value of the WCTEMP or CCTEMP
|
||||
field is 0h, then this field is always cleared to 0h
|
||||
regardless of the Composite Temperature value.
|
||||
.IP "critical_comp_time" 12
|
||||
Critical Composite Temperature Time: Contains the amount
|
||||
of time in minutes that the controller is operational
|
||||
and the Composite Temperature is greater than or equal
|
||||
to the Critical Composite Temperature Threshold (CCTEMP)
|
||||
field in the Identify Controller data structure. If
|
||||
the value of the CCTEMP field is 0h, then this field
|
||||
is always cleared to 0h regardless of the Composite
|
||||
Temperature value.
|
||||
.IP "temp_sensor" 12
|
||||
Temperature Sensor 1-8: Contains the current temperature
|
||||
in degrees Kelvin reported by temperature sensors 1-8.
|
||||
The physical point in the NVM subsystem whose temperature
|
||||
is reported by the temperature sensor and the temperature
|
||||
accuracy is implementation specific. An implementation
|
||||
that does not implement the temperature sensor reports
|
||||
a value of 0h.
|
||||
.IP "thm_temp1_trans_count" 12
|
||||
Thermal Management Temperature 1 Transition Count:
|
||||
Contains the number of times the controller transitioned
|
||||
to lower power active power states or performed vendor
|
||||
specific thermal management actions while minimizing
|
||||
the impact on performance in order to attempt to reduce
|
||||
the Composite Temperature because of the host controlled
|
||||
thermal management feature (i.e., the Composite
|
||||
Temperature rose above the Thermal Management
|
||||
Temperature 1). This counter shall not wrap once the
|
||||
value FFFFFFFFh is reached. A value of 0h, indicates
|
||||
that this transition has never occurred or this field
|
||||
is not implemented.
|
||||
.IP "thm_temp2_trans_count" 12
|
||||
Thermal Management Temperature 2 Transition Count
|
||||
.IP "thm_temp1_total_time" 12
|
||||
Total Time For Thermal Management Temperature 1:
|
||||
Contains the number of seconds that the controller
|
||||
had transitioned to lower power active power states or
|
||||
performed vendor specific thermal management actions
|
||||
while minimizing the impact on performance in order to
|
||||
attempt to reduce the Composite Temperature because of
|
||||
the host controlled thermal management feature. This
|
||||
counter shall not wrap once the value FFFFFFFFh is
|
||||
reached. A value of 0h, indicates that this transition
|
||||
has never occurred or this field is not implemented.
|
||||
.IP "thm_temp2_total_time" 12
|
||||
Total Time For Thermal Management Temperature 2
|
||||
.IP "rsvd232" 12
|
||||
Reserved
|