Adding upstream version 1.12.
Signed-off-by: Daniel Baumann <daniel@debian.org>
This commit is contained in:
parent
3b95ae912c
commit
ac60c09ef6
457 changed files with 159628 additions and 0 deletions
157
Documentation/nvme-connect.txt
Normal file
157
Documentation/nvme-connect.txt
Normal file
|
@ -0,0 +1,157 @@
|
|||
nvme-connect(1)
|
||||
===============
|
||||
|
||||
NAME
|
||||
----
|
||||
nvme-connect - Connect to a Fabrics controller.
|
||||
|
||||
SYNOPSIS
|
||||
--------
|
||||
[verse]
|
||||
'nvme connect'
|
||||
[--transport=<trtype> | -t <trtype>]
|
||||
[--nqn=<subnqn> | -n <subnqn>]
|
||||
[--traddr=<traddr> | -a <traddr>]
|
||||
[--trsvcid=<trsvcid> | -s <trsvcid>]
|
||||
[--host-traddr=<traddr> | -w <traddr>]
|
||||
[--hostnqn=<hostnqn> | -q <hostnqn>]
|
||||
[--hostid=<hostid> | -I <hostid>]
|
||||
[--nr-io-queues=<#> | -i <#>]
|
||||
[--nr-write-queues=<#> | -W <#>]
|
||||
[--nr-poll-queues=<#> | -P <#>]
|
||||
[--queue-size=<#> | -Q <#>]
|
||||
[--keep-alive-tmo=<#> | -k <#>]
|
||||
[--reconnect-delay=<#> | -c <#>]
|
||||
[--ctrl-loss-tmo=<#> | -l <#>]
|
||||
[--duplicate-connect | -D]
|
||||
[--disable-sqflow | -d]
|
||||
[--hdr-digest | -g]
|
||||
[--data-digest | -G]
|
||||
|
||||
DESCRIPTION
|
||||
-----------
|
||||
Create a transport connection to a remote system (specified by --traddr and
|
||||
--trsvcid) and create a NVMe over Fabrics controller for the NVMe subsystem
|
||||
specified by the --nqn option.
|
||||
|
||||
OPTIONS
|
||||
-------
|
||||
-t <trtype>::
|
||||
--transport=<trtype>::
|
||||
This field specifies the network fabric being used for
|
||||
a NVMe-over-Fabrics network. Current string values include:
|
||||
+
|
||||
[]
|
||||
|=================
|
||||
|Value|Definition
|
||||
|rdma|The network fabric is an rdma network (RoCE, iWARP, Infiniband, basic rdma, etc)
|
||||
|fc |*WIP* The network fabric is a Fibre Channel network.
|
||||
|loop|Connect to a NVMe over Fabrics target on the local host
|
||||
|=================
|
||||
|
||||
-n <subnqn>::
|
||||
--nqn <subnqn>::
|
||||
This field specifies the name for the NVMe subsystem to connect to.
|
||||
|
||||
-a <traddr>::
|
||||
--traddr=<traddr>::
|
||||
This field specifies the network address of the Controller.
|
||||
For transports using IP addressing (e.g. rdma) this should be an
|
||||
IP-based address (ex. IPv4).
|
||||
|
||||
-s <trsvcid>::
|
||||
--trsvcid=<trsvcid>::
|
||||
This field specifies the transport service id. For transports using IP
|
||||
addressing (e.g. rdma) this field is the port number. By default, the IP
|
||||
port number for the RDMA transport is 4420.
|
||||
|
||||
-w <traddr>::
|
||||
--host-traddr=<traddr>::
|
||||
This field specifies the network address used on the host to connect
|
||||
to the Controller.
|
||||
|
||||
-q <hostnqn>::
|
||||
--hostnqn=<hostnqn>::
|
||||
Overrides the default Host NQN that identifies the NVMe Host.
|
||||
If this option is not specified, the default is read from
|
||||
/etc/nvme/hostnqn first. If that does not exist, the autogenerated
|
||||
NQN value from the NVMe Host kernel module is used next.
|
||||
The Host NQN uniquely identifies the NVMe Host.
|
||||
|
||||
-I <hostid>::
|
||||
--hostid=<hostid>::
|
||||
UUID(Universally Unique Identifier) to be discovered which should be
|
||||
formatted.
|
||||
|
||||
-i <#>::
|
||||
--nr-io-queues=<#>::
|
||||
Overrides the default number of I/O queues create by the driver.
|
||||
|
||||
-W <#>::
|
||||
--nr-write-queues=<#>::
|
||||
Adds additional queues that will be used for write I/O.
|
||||
|
||||
-P <#>::
|
||||
--nr-poll-queues=<#>::
|
||||
Adds additional queues that will be used for polling latency sensitive I/O.
|
||||
|
||||
-Q <#>::
|
||||
--queue-size=<#>::
|
||||
Overrides the default number of elements in the I/O queues created
|
||||
by the driver.
|
||||
|
||||
-k <#>::
|
||||
--keep-alive-tmo=<#>::
|
||||
Overrides the default keep alive timeout (in seconds).
|
||||
|
||||
-c <#>::
|
||||
--reconnect-delay=<#>::
|
||||
Overrides the default delay (in seconds) before reconnect is attempted
|
||||
after a connect loss.
|
||||
|
||||
-l <#>::
|
||||
--ctrl-loss-tmo=<#>::
|
||||
Overrides the default controller loss timeout period (in seconds).
|
||||
|
||||
-D::
|
||||
--duplicate-connect::
|
||||
Allows duplicated connections between same trnsport host and subsystem
|
||||
port.
|
||||
|
||||
-d::
|
||||
--disable-sqflow::
|
||||
Disables SQ flow control to omit head doorbell update for submission
|
||||
queues when sending nvme completions.
|
||||
|
||||
-g::
|
||||
--hdr-digest::
|
||||
Generates/verifies header digest (TCP).
|
||||
|
||||
-G::
|
||||
--data-digest::
|
||||
Generates/verifies data digest (TCP).
|
||||
|
||||
EXAMPLES
|
||||
--------
|
||||
* Connect to a subsystem named nqn.2014-08.com.example:nvme:nvm-subsystem-sn-d78432
|
||||
on the IP4 address 192.168.1.3. Port 4420 is used by default:
|
||||
+
|
||||
------------
|
||||
# nvme connect --transport=rdma --traddr=192.168.1.3 \
|
||||
--nqn=nqn.2014-08.com.example:nvme:nvm-subsystem-sn-d78432
|
||||
------------
|
||||
|
||||
SEE ALSO
|
||||
--------
|
||||
nvme-discover(1)
|
||||
nvme-connect-all(1)
|
||||
|
||||
|
||||
AUTHORS
|
||||
-------
|
||||
This was co-written by mailto:james.p.freyensee@intel.com[Jay Freyensee]
|
||||
and mailto:hch@lst.de[Christoph Hellwig]
|
||||
|
||||
NVME
|
||||
----
|
||||
Part of the nvme-user suite
|
Loading…
Add table
Add a link
Reference in a new issue