1
0
Fork 0

Merging upstream version 1.15.

Signed-off-by: Daniel Baumann <daniel@debian.org>
This commit is contained in:
Daniel Baumann 2025-02-16 12:11:43 +01:00
parent 14665a711e
commit d975eb29d0
Signed by: daniel
GPG key ID: FBB4F0E80A80222F
116 changed files with 6031 additions and 2284 deletions

View file

@ -13,6 +13,7 @@ SYNOPSIS
[--traddr=<traddr> | -a <traddr>]
[--trsvcid=<trsvcid> | -s <trsvcid>]
[--host-traddr=<traddr> | -w <traddr>]
[--host-iface=<iface> | -f <iface>]
[--hostnqn=<hostnqn> | -q <hostnqn>]
[--hostid=<hostid> | -I <hostid>]
[--raw=<filename> | -r <filename>]
@ -35,7 +36,7 @@ DESCRIPTION
Send one or more Get Log Page requests to a NVMe-over-Fabrics Discovery
Controller.
If no parameters are given, then 'nvme discover' will attempt to
If no parameters are given, then 'nvme discover' will attempt to
find a /etc/nvme/discovery.conf file to use to supply a list of
Discovery commands to run. If no /etc/nvme/discovery.conf file
exists, the command will quit with an error.
@ -46,7 +47,7 @@ request will then be sent to the specified Discovery Controller.
BACKGROUND
----------
The NVMe-over-Fabrics specification defines the concept of a
The NVMe-over-Fabrics specification defines the concept of a
Discovery Controller that an NVMe Host can query on a fabric
network to discover NVMe subsystems contained in NVMe Targets
which it can connect to on the network. The Discovery Controller
@ -66,7 +67,7 @@ resources are allocated to the NVMe Host for a connection.
A Discovery Controller has it's own NQN defined in the NVMe-over-Fabrics
specification, *nqn.2014-08.org.nvmexpress.discovery*. All Discovery
Controllers must use this NQN name. This NQN is used by default by
nvme-cli for the 'discover' command.
nvme-cli for the 'discover' command.
OPTIONS
-------
@ -99,11 +100,18 @@ OPTIONS
-w <traddr>::
--host-traddr=<traddr>::
This field specifies the network address used on the host to connect
to the Discovery Controller.
to the Controller. For TCP, this sets the source address on the socket.
-f <iface>::
--host-iface=<iface>::
This field specifies the network interface used on the host to connect
to the Controller (e.g. IP eth1, enp2s0, enx78e7d1ea46da). This forces
the connection to be made on a specific interface instead of letting
the system decide.
-q <hostnqn>::
--hostnqn=<hostnqn>::
Overrides the default host NQN that identifies the NVMe Host.
Overrides the default host NQN that identifies the NVMe Host.
If this option is not specified, the default is read from
/etc/nvme/hostnqn first. If that does not exist, the autogenerated
NQN value from the NVMe Host kernel module is used next.