<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE refentry PUBLIC "-//OASIS//DTD DocBook XML V4.5//EN"
"http://www.oasis-open.org/docbook/xml/4.2/docbookx.dtd" [
<!ENTITY daemon "stacd">
<!ENTITY deamondesc "STorage Appliance Connector">
<!ENTITY control "stacctl">
]>

<!--
    SPDX-License-Identifier: Apache-2.0
    Copyright (c) 2021, Dell Inc. or its subsidiaries.  All rights reserved.
-->

<refentry id="&daemon;" xmlns:xi="http://www.w3.org/2001/XInclude">
    <refentryinfo>
        <title>&daemon;</title>
        <productname>nvme-stas</productname>
        <author>
            <personname>
                <honorific>Mr</honorific>
                <firstname>Martin</firstname>
                <surname>Belanger</surname>
            </personname>
            <affiliation>
                <orgname>Dell, Inc.</orgname>
            </affiliation>
        </author>
    </refentryinfo>

    <refmeta>
        <refentrytitle>&daemon;</refentrytitle>
        <manvolnum>8</manvolnum>
    </refmeta>

    <refnamediv>
        <refname>&daemon;</refname>
        <refpurpose>&deamondesc;</refpurpose>
    </refnamediv>

    <refsynopsisdiv>
        <cmdsynopsis>
            <command>&daemon;</command>
            <arg choice="opt" rep="repeat">OPTIONS</arg>
        </cmdsynopsis>
    </refsynopsisdiv>

    <refsect1>
        <title>Description</title>

        <para>
            <command>&daemon;</command>
            is a system daemon that can be used to automatically connect to
            NVMe-oF I/O Controllers using the discovery log pages collected by
            <citerefentry>
                <refentrytitle>stafd</refentrytitle>
                <manvolnum>8</manvolnum>
            </citerefentry>. It can also be manually configured with
            <citerefentry>
                <refentrytitle>&daemon;.conf</refentrytitle>
                <manvolnum>5</manvolnum>
            </citerefentry>
            to connect to I/O Controllers that otherwise cannot be found
            automatically.
        </para>
    </refsect1>

    <refsect1>
        <title>Options</title>
        <para>The following options are understood:</para>

        <variablelist>
            <xi:include href="standard-options.xml" xpointer="help"/>
            <xi:include href="standard-options.xml" xpointer="version"/>
        </variablelist>

        <varlistentry>
            <term><option>-fFILE</option></term>
            <term><option>--conf-file=FILE</option></term>
            <listitem>
                <para>
                    Specify a different configuration file than
                    <citerefentry>
                        <refentrytitle>&daemon;.conf</refentrytitle>
                        <manvolnum>5</manvolnum>
                    </citerefentry>
                    (default: <filename>/etc/stas/&daemon;.conf</filename>).
                </para>
            </listitem>
        </varlistentry>

        <varlistentry>
            <term><option>-s</option></term>
            <term><option>--syslog</option></term>
            <listitem>
                <para>
                    Send messages to syslog instead of stdout. Use this when
                    running &daemon; as a daemon. (default: <literal>false</literal>).
                </para>
            </listitem>
        </varlistentry>

        <varlistentry>
            <term><option>--tron</option></term>
            <listitem>
                <para>Trace ON. (default: <literal>false</literal>)</para>
            </listitem>
        </varlistentry>

        <varlistentry>
            <term><option>--idl=FILE</option></term>
            <listitem>
                <para>Print D-Bus IDL to FILE and exit.</para>
            </listitem>
        </varlistentry>
    </refsect1>

    <refsect1>
        <title>Exit status</title>
        <para>
            On success, 0 is returned, a non-zero failure code otherwise.
        </para>
    </refsect1>

    <refsect1>
        <title>Daemonization</title>
        <para>
            &daemon; is managed by <code>systemd</code>. The following
            operations are supported:
        </para>

        <table align='left' frame='all'>
            <tgroup cols="2" align='left' colsep='1' rowsep='1'>
                <thead>
                    <row>
                        <entry>Command</entry>
                        <entry>Description</entry>
                    </row>
                </thead>

                <tbody>
                    <row>
                        <entry><programlisting>$ systemctl start &daemon; </programlisting></entry>
                        <entry>Start daemon.</entry>
                    </row>

                    <row>
                        <entry><programlisting>$ systemctl stop &daemon; </programlisting></entry>
                        <entry>Stop daemon. The <code>SIGTERM</code> signal is used to tell the daemon to stop.</entry>
                    </row>

                    <row>
                        <entry><programlisting>$ systemctl restart &daemon; </programlisting></entry>
                        <entry>Effectively a <code>stop</code> + <code>start</code>.</entry>
                    </row>

                    <row>
                        <entry><programlisting>$ systemctl reload &daemon; </programlisting></entry>
                        <entry>Reload configuration. This is done in real time without restarting the daemon. The <code>SIGHUP</code> signal is used to tell the daemon to reload its configuration file. Note that configuration parameters that affect connections (e.g. <code>kato</code>), will not apply to existing connections. Only connections established after the configuration was changed will utilize the new configuration parameters.</entry>
                    </row>
                </tbody>
            </tgroup>
        </table>
    </refsect1>

    <refsect1>
      <title>Design</title>

      <para>
          <command>&daemon;</command> use the <code>GLib</code> main loop.
          The <code>GLib</code> Python module provides several low-level
          building blocks that <command>&daemon;</command> requires. In
          addition, many Python modules "play nice" with <code>GLib</code>
          such as <code>dasbus</code> (D-Bus package) and <code>pyudev</code>
          (UDev package). <code>GLib</code> also provides additional components
          such as timers, signal handlers, and much more.
      </para>
    </refsect1>

    <refsect1>
        <title>Configuration</title>
        <para>
            <command>&daemon;</command> can automatically set up the I/O
            connections to discovered storage subsystems. However,
            <command>&daemon;</command> can also operate in a non-automatic
            mode based on manually entered configuration. In other words,
            storage subsystems can be entered in a configuration file named
            <filename>/etc/stas/&daemon;.conf</filename>.
            This configuration file also provides additional parameters,
            as log-level attributes used for debugging purposes.
        </para>
    </refsect1>

    <refsect1>
        <title>D-Bus API</title>
        <para>
            The interface to <command>&daemon;</command> is D-Bus.
            This allows other programs, such as <command>&control;</command>,
            to communicate with <command>&daemon;</command>. The D-Bus address
            is <code>org.nvmexpress.stac</code>.
        </para>
    </refsect1>

    <refsect1>
        <title>See Also</title>

        <para>
            <citerefentry>
                <refentrytitle>&daemon;.conf</refentrytitle>
                <manvolnum>5</manvolnum>
            </citerefentry>,
            <citerefentry>
                <refentrytitle>&daemon;.service</refentrytitle>
                <manvolnum>8</manvolnum>
            </citerefentry>,
            <citerefentry>
                <refentrytitle>stacctl</refentrytitle>
                <manvolnum>1</manvolnum>
            </citerefentry>,
            <citerefentry>
                <refentrytitle>stafd</refentrytitle>
                <manvolnum>8</manvolnum>
            </citerefentry>,
            <citerefentry>
                <refentrytitle>org.nvmexpress.stac</refentrytitle>
                <manvolnum>5</manvolnum>
            </citerefentry>.
        </para>
    </refsect1>
</refentry>