# UPSD Input Plugin
|
|
|
|
This plugin reads data of one or more Uninterruptible Power Supplies
|
|
from an `upsd` daemon using its NUT network protocol.
|
|
|
|
## Requirements
|
|
|
|
`upsd` should be installed and it's daemon should be running.
|
|
|
|
## Global configuration options <!-- @/docs/includes/plugin_config.md -->
|
|
|
|
In addition to the plugin-specific configuration settings, plugins support
|
|
additional global and plugin configuration settings. These settings are used to
|
|
modify metrics, tags, and field or create aliases and configure ordering, etc.
|
|
See the [CONFIGURATION.md][CONFIGURATION.md] for more details.
|
|
|
|
[CONFIGURATION.md]: ../../../docs/CONFIGURATION.md#plugins
|
|
|
|
## Configuration
|
|
|
|
```toml @sample.conf
|
|
# Monitor UPSes connected via Network UPS Tools
|
|
[[inputs.upsd]]
|
|
## A running NUT server to connect to.
|
|
## IPv6 addresses must be enclosed in brackets (e.g. "[::1]")
|
|
# server = "127.0.0.1"
|
|
# port = 3493
|
|
# username = "user"
|
|
# password = "password"
|
|
|
|
## Force parsing numbers as floats
|
|
## It is highly recommended to enable this setting to parse numbers
|
|
## consistently as floats to avoid database conflicts where some numbers are
|
|
## parsed as integers and others as floats.
|
|
# force_float = false
|
|
|
|
## Collect additional fields if they are available for the UPS
|
|
## The fields need to be specified as NUT variable names, see
|
|
## https://networkupstools.org/docs/developer-guide.chunked/apas02.html
|
|
## Wildcards are accepted.
|
|
# additional_fields = []
|
|
|
|
## Dump information for debugging
|
|
## Allows to print the raw variables (and corresponding types) as received
|
|
## from the NUT server ONCE for each UPS.
|
|
## Please attach this information when reporting issues!
|
|
# log_level = "trace"
|
|
```
|
|
|
|
## Pitfalls
|
|
|
|
Please note that field types are automatically determined based on the values.
|
|
Especially the strings `enabled` and `disabled` are automatically converted to
|
|
`boolean` values. This might lead to trouble for fields that can contain
|
|
non-binary values like `enabled`, `disabled` and `muted` as the output field
|
|
will be `boolean` for the first two values but `string` for the latter. To
|
|
convert `enabled` and `disabled` values back to `string` for those fields, use
|
|
the [enum processor][enum_processor] with
|
|
|
|
```toml
|
|
[[processors.enum]]
|
|
[[processors.enum.mapping]]
|
|
field = "ups_beeper_status"
|
|
[processors.enum.mapping.value_mappings]
|
|
true = "enabled"
|
|
false = "disabled"
|
|
```
|
|
|
|
Alternatively, you can also map the non-binary value to a `boolean`.
|
|
|
|
[enum_processor]: ../../processors/enum/README.md
|
|
|
|
## Metrics
|
|
|
|
This implementation tries to maintain compatibility with the apcupsd metrics:
|
|
|
|
- upsd
|
|
- tags:
|
|
- serial
|
|
- ups_name
|
|
- model
|
|
- fields:
|
|
- status_flags ([status-bits][rfc9271-sec5.1])
|
|
- input_voltage
|
|
- load_percent
|
|
- battery_charge_percent
|
|
- time_left_ns
|
|
- output_voltage
|
|
- internal_temp
|
|
- battery_voltage
|
|
- input_frequency
|
|
- battery_date
|
|
- nominal_input_voltage
|
|
- nominal_battery_voltage
|
|
- nominal_power
|
|
- firmware
|
|
|
|
With the exception of:
|
|
|
|
- tags:
|
|
- status (string representing the set status_flags)
|
|
- fields:
|
|
- time_on_battery_ns
|
|
|
|
[rfc9271-sec5.1]: https://www.rfc-editor.org/rfc/rfc9271.html#section-5.1
|
|
|
|
## Example Output
|
|
|
|
```text
|
|
upsd,serial=AS1231515,ups_name=name1 load_percent=9.7,time_left_ns=9800000,output_voltage=230.4,internal_temp=32.4,battery_voltage=27.4,input_frequency=50.2,input_voltage=230.4,battery_charge_percent=100,status_flags=8i 1490035922000000000
|
|
```
|