# Clarify Output Plugin
|
|
|
|
This plugin writes metrics to [Clarify][clarify]. To use this plugin you will
|
|
need to obtain a set of [credentials][credentials].
|
|
|
|
⭐ Telegraf v1.27.0
|
|
🏷️ cloud, datastore
|
|
💻 all
|
|
|
|
## Global configuration options <!-- @/docs/includes/plugin_config.md -->
|
|
|
|
In addition to the plugin-specific configuration settings, plugins support
|
|
additional global and plugin configuration settings. These settings are used to
|
|
modify metrics, tags, and field or create aliases and configure ordering, etc.
|
|
See the [CONFIGURATION.md][CONFIGURATION.md] for more details.
|
|
|
|
[CONFIGURATION.md]: ../../../docs/CONFIGURATION.md#plugins
|
|
|
|
## Configuration
|
|
|
|
```toml @sample.conf
|
|
## Configuration to publish Telegraf metrics to Clarify
|
|
[[outputs.clarify]]
|
|
## Credentials File (Oauth 2.0 from Clarify integration)
|
|
credentials_file = "/path/to/clarify/credentials.json"
|
|
|
|
## Clarify username password (Basic Auth from Clarify integration)
|
|
username = "i-am-bob"
|
|
password = "secret-password"
|
|
|
|
## Timeout for Clarify operations
|
|
# timeout = "20s"
|
|
|
|
## Optional tags to be included when generating the unique ID for a signal in Clarify
|
|
# id_tags = []
|
|
# clarify_id_tag = 'clarify_input_id'
|
|
```
|
|
|
|
You can use either a credentials file or username/password.
|
|
If both are present and valid in the configuration the
|
|
credentials file will be used.
|
|
|
|
## How Telegraf Metrics map to Clarify signals
|
|
|
|
Clarify signal names are formed by joining the Telegraf metric name and the
|
|
field key with a `.` character. Telegraf tags are added to signal labels.
|
|
|
|
If you wish to specify a specific tag to use as the input id, set the config
|
|
option `clarify_id_tag` to the tag containing the id to be used.
|
|
If this tag is present and there is only one field present in the metric,
|
|
this tag will be used as the inputID in Clarify. If there are more fields
|
|
available in the metric, the tag will be ignored and normal id generation
|
|
will be used.
|
|
|
|
If information from one or several tags is needed to uniquely identify a metric
|
|
field, the id_tags array can be added to the config with the needed tag names.
|
|
E.g:
|
|
|
|
`id_tags = ['sensor']`
|
|
|
|
Clarify only supports values that can be converted to floating point numbers.
|
|
Strings and invalid numbers are ignored.
|
|
|
|
## Example
|
|
|
|
The following input would be stored in Clarify with the values shown below:
|
|
|
|
```text
|
|
temperature,host=demo.clarifylocal,sensor=TC0P value=49 1682670910000000000
|
|
```
|
|
|
|
```json
|
|
"signal" {
|
|
"id": "temperature.value.TC0P"
|
|
"name": "temperature.value"
|
|
"labels": {
|
|
"host": ["demo.clarifylocal"],
|
|
"sensor": ["TC0P"]
|
|
}
|
|
}
|
|
"values" {
|
|
"times": ["2023-04-28T08:43:16+00:00"],
|
|
"series": {
|
|
"temperature.value.TC0P": [49]
|
|
}
|
|
}
|
|
```
|
|
|
|
[clarify]: https://clarify.io
|
|
[credentials]: https://docs.clarify.io/users/admin/integrations/credentials
|