Adding upstream version 2.2.1.
Signed-off-by: Daniel Baumann <daniel@debian.org>
This commit is contained in:
parent
1d36de0179
commit
757b718eff
129 changed files with 16110 additions and 0 deletions
322
etc/stas/stacd.conf
Normal file
322
etc/stas/stacd.conf
Normal file
|
@ -0,0 +1,322 @@
|
|||
# Copyright (c) 2021, Dell Inc. or its subsidiaries. All rights reserved.
|
||||
# SPDX-License-Identifier: Apache-2.0
|
||||
# See the LICENSE file for details.
|
||||
#
|
||||
# This file is part of NVMe STorage Appliance Services (nvme-stas).
|
||||
|
||||
# ==============================================================================
|
||||
# STorage Appliance Connector Daemon (stacd) - configuration file
|
||||
#
|
||||
# In this file, options that are commented represent the default values used.
|
||||
# Uncommented options override the default value.
|
||||
|
||||
|
||||
[Global]
|
||||
# tron: Trace-ON. Enable additional debug info
|
||||
# Type: boolean
|
||||
# Range: [false, true]
|
||||
#tron=false
|
||||
|
||||
# hdr-digest: Protocol Data Unit (PDU) Header Digest. NVMe/TCP facilitates an
|
||||
# optional PDU Header digest. Digests are calculated using the
|
||||
# CRC32C algorithm.
|
||||
# Type: boolean
|
||||
# Range: [false, true]
|
||||
#hdr-digest=false
|
||||
|
||||
# data-digest: Protocol Data Unit (PDU) Data Digest. NVMe/TCP facilitates an
|
||||
# optional PDU Data digest. Digests are calculated using the
|
||||
# CRC32C algorithm.
|
||||
# Type: boolean
|
||||
# Range: [false, true]
|
||||
#data-digest=false
|
||||
|
||||
# kato: Keep Alive Timeout (KATO): This field specifies the timeout value
|
||||
# for the Keep Alive feature in seconds. The default value for this
|
||||
# field is 30 seconds (2 minutes).
|
||||
# Type: Unsigned integer
|
||||
# Range: 0..N
|
||||
# Unit: Seconds
|
||||
#kato=30
|
||||
|
||||
# nr-io-queues: Overrides the default number of I/O queues create by the
|
||||
# driver.
|
||||
# Type: Unsigned integer
|
||||
# Range: 1..N
|
||||
# Default: Depends on kernel and other run time
|
||||
# factors (e.g. number of CPUs).
|
||||
|
||||
# nr-write-queues: Adds additional queues that will be used for write I/O.
|
||||
# Type: Unsigned integer
|
||||
# Range: 1..N
|
||||
# Default: Depends on kernel and other run time
|
||||
# factors (e.g. number of CPUs).
|
||||
|
||||
# nr-poll-queues: Adds additional queues that will be used for polling
|
||||
# latency sensitive I/O.
|
||||
# Type: Unsigned integer
|
||||
# Range: 1..N
|
||||
# Default: Depends on kernel and other run time
|
||||
# factors (e.g. number of CPUs).
|
||||
|
||||
# queue-size: Overrides the default number of elements in the I/O queues
|
||||
# created by the driver.
|
||||
# Type: Unsigned integer
|
||||
# Range: 16..1024
|
||||
# Default: 128
|
||||
#queue-size=128
|
||||
|
||||
# reconnect-delay: Overrides the default delay, in seconds, before reconnect
|
||||
# is attempted after a connect loss.
|
||||
# Type: Unsigned integer
|
||||
# Range: 1..N
|
||||
# Unit: Seconds
|
||||
# Default: 10 (retry to connect every 10 seconds)
|
||||
#reconnect-delay=10
|
||||
|
||||
# ctrl-loss-tmo: Overrides the default controller loss timeout period in
|
||||
# seconds.
|
||||
# Type: Unsigned integer
|
||||
# Range: -1, 0..N where -1 means retry forever
|
||||
# Unit: Seconds
|
||||
# Default: 600 (retry to connect for up to 10 minutes)
|
||||
#ctrl-loss-tmo=600
|
||||
|
||||
# disable-sqflow: Disables SQ flow control to omit head doorbell update for
|
||||
# submission queues when sending nvme completions.
|
||||
# Type: boolean
|
||||
# Range: [false, true]
|
||||
# Default: false
|
||||
#disable-sqflow=false
|
||||
|
||||
# ignore-iface: This option controls whether connections with I/O Controllers
|
||||
# (IOC) will be forced on a specific interface or will rely on
|
||||
# the routing tables to determine the interface.
|
||||
#
|
||||
# See the man pages for details: man stacd.conf
|
||||
#
|
||||
# Type: boolean
|
||||
# Range: [false, true]
|
||||
# Default: true
|
||||
#ignore-iface=false
|
||||
|
||||
# ip-family: With this you can specify whether stacd will support IPv4, IPv6,
|
||||
# or both when connecting to I/O Controllers (IOC).
|
||||
#
|
||||
# See the man pages for details: man stacd.conf
|
||||
#
|
||||
# Type: String
|
||||
# Range: [ipv4, ipv6, ipv4+ipv6]
|
||||
# Default: ipv4+ipv6
|
||||
#ip-family=ipv4+ipv6
|
||||
|
||||
|
||||
# ==============================================================================
|
||||
[I/O controller connection management]
|
||||
# This section contains parameters to manage I/O controller connections.
|
||||
# For example, parameters are provided to control disconnect policy. In other
|
||||
# words, whether stacd will disconnect from IOCs on DLPE removal and which
|
||||
# connections will be affected.
|
||||
#
|
||||
# Also, what should stacd do when a DLPE NCC bit (Not Connected to CDC) is
|
||||
# asserted. Should stacd stop trying to connect to an I/O controller after a
|
||||
# certain number of unsuccessful attempts.
|
||||
#
|
||||
# See the man pages for details: man stacd.conf
|
||||
|
||||
# disconnect-scope: Determines which connections, if any, will be the target of
|
||||
# a potential disconnect on DLPE removal.
|
||||
#
|
||||
# Type: String
|
||||
# Range: [only-stas-connections | all-connections-matching-disconnect-trtypes | no-disconnect]
|
||||
# Default: only-stas-connections
|
||||
#disconnect-scope=only-stas-connections
|
||||
|
||||
# disconnect-trtypes: Specify which connections should be audited based on the
|
||||
# transport type. This parameter only applies when
|
||||
# "disconnect-scope = all-connections-matching-disconnect-trtypes".
|
||||
#
|
||||
# Type: String
|
||||
# Range: [tcp, rdma, fc, tcp+rdma, tcp+fc, rdma+fc, tcp+rdma+fc]
|
||||
# Default: tcp
|
||||
#disconnect-trtypes=tcp
|
||||
|
||||
# connect-attempts-on-ncc: The NCC bit (Not Connected to CDC) returned in a
|
||||
# DLPE indicates whether a connection is currently
|
||||
# established between the CDC and the subsystem listed
|
||||
# in the DLPE.
|
||||
#
|
||||
# When the NCC bit is asserted, it may mean that the
|
||||
# subsystem is offline or that fabrics connectivity is
|
||||
# momentarily lost. If the host is also unable to
|
||||
# connect to the subsystem, then there is no point in
|
||||
# continuing to try to connect. In fact, the CDC will
|
||||
# monitor the situation an inform the host (AEN) when
|
||||
# connectivity is restored.
|
||||
#
|
||||
# This field is used to tell stacd how to behave when
|
||||
# the NCC bit is asserted. How many times should it try
|
||||
# to connect before give-up, or whether to keep trying
|
||||
# indefinitely.
|
||||
#
|
||||
# Type: Integer
|
||||
# Range: [0, 2..N], 0 means "Never stop trying". A
|
||||
# non-0 value indicates the number of attempts
|
||||
# before giving up. This value should never be
|
||||
# set to 1. A value of 1 will automatically be
|
||||
# increased to 2. That's because a single
|
||||
# failure may be normal and a mimimum of 2
|
||||
# attempts is required to conclude that a
|
||||
# connection is not possible.
|
||||
# Default: 0
|
||||
#connect-attempts-on-ncc=0
|
||||
|
||||
# ==============================================================================
|
||||
[Controllers]
|
||||
# controller: I/O Controllers (IOC) are specified with this keyword.
|
||||
#
|
||||
# Syntax:
|
||||
# controller = transport=<trtype>;traddr=<traddr>;trsvcid=<trsvcid>;host-traddr=<traddr>;host-iface=<iface>,nqn=<subnqn>
|
||||
#
|
||||
# transport=<trtype> [MANDATORY]
|
||||
# This field specifies the network fabric being used for a NVMe-over-
|
||||
# Fabrics network. Current string values include:
|
||||
#
|
||||
# Value Definition
|
||||
# ------- -----------------------------------------------------------
|
||||
# rdma The network fabric is an rdma network (RoCE, iWARP, Infiniband, basic rdma, etc)
|
||||
# fc The network fabric is a Fibre Channel network.
|
||||
# tcp The network fabric is a TCP/IP network.
|
||||
# loop Connect to a NVMe over Fabrics target on the local host
|
||||
#
|
||||
# traddr=<traddr> [MANDATORY]
|
||||
# This field specifies the network address of the Controller. For
|
||||
# transports using IP addressing (e.g. rdma) this should be an IP-
|
||||
# based address (ex. IPv4, IPv6). It could also be a resolvable host
|
||||
# name (e.g. localhost).
|
||||
#
|
||||
# nqn=<subnqn> [MANDATORY]
|
||||
# This field specifies the Subsystem's NVMe Qualified Name.
|
||||
#
|
||||
# trsvcid=<trsvcid> [OPTIONAL]
|
||||
# This field specifies the transport service id. For transports using
|
||||
# IP addressing (e.g. rdma) this field is the port number.
|
||||
#
|
||||
# Depending on the transport type, this field will default to either
|
||||
# 8009 or 4420 as follows.
|
||||
#
|
||||
# UDP port 4420 and TCP port 4420 have been assigned by IANA
|
||||
# for use by NVMe over Fabrics. NVMe/RoCEv2 controllers use UDP port
|
||||
# 4420 by default. NVMe/iWARP controllers use TCP port 4420 by
|
||||
# default.
|
||||
#
|
||||
# TCP port 4420 has been assigned for use by NVMe over Fabrics and TCP
|
||||
# port 8009 has been assigned by IANA for use by NVMe over Fabrics
|
||||
# discovery. TCP port 8009 is the default TCP port for NVMe/TCP
|
||||
# discovery controllers. There is no default TCP port for NVMe/TCP I/O
|
||||
# controllers, the Transport Service Identifier (TRSVCID) field in the
|
||||
# Discovery Log Entry indicates the TCP port to use.
|
||||
#
|
||||
# The TCP ports that may be used for NVMe/TCP I/O controllers include
|
||||
# TCP port 4420, and the Dynamic and/or Private TCP ports (i.e., ports
|
||||
# in the TCP port number range from 49152 to 65535). NVMe/TCP I/O
|
||||
# controllers should not use TCP port 8009. TCP port 4420 shall not be
|
||||
# used for both NVMe/iWARP and NVMe/TCP at the same IP address on the
|
||||
# same network.
|
||||
#
|
||||
# host-traddr=<traddr> [OPTIONAL]
|
||||
# This field specifies the network address used on the host to connect
|
||||
# to the Controller. For TCP, this sets the source address on the
|
||||
# socket.
|
||||
#
|
||||
# host-iface=<iface> [OPTIONAL]
|
||||
# This field specifies the network interface used on the host to
|
||||
# connect to the Controller (e.g. IP eth1, enp2s0, enx78e7d1ea46da).
|
||||
# This forces the connection to be made on a specific interface
|
||||
# instead of letting the system decide.
|
||||
#
|
||||
# dhchap-ctrl-secret [OPTIONAL]
|
||||
# NVMe In-band authentication controller secret (i.e. key) for
|
||||
# bi-directional authentication; needs to be in ASCII format as
|
||||
# specified in NVMe 2.0 section 8.13.5.8 'Secret representation'.
|
||||
# Bi-directional authentication will be attempted when present.
|
||||
#
|
||||
# hdr-digest [OPTIONAL]
|
||||
# See definition in [Global] section. This is used to override
|
||||
# the value specified in the [Global] section.
|
||||
#
|
||||
# data-digest [OPTIONAL]
|
||||
# See definition in [Global] section. This is used to override
|
||||
# the value specified in the [Global] section.
|
||||
#
|
||||
# nr-io-queues [OPTIONAL]
|
||||
# See definition in [Global] section. This is used to override
|
||||
# the value specified in the [Global] section.
|
||||
#
|
||||
# nr-write-queues [OPTIONAL]
|
||||
# See definition in [Global] section. This is used to override
|
||||
# the value specified in the [Global] section.
|
||||
#
|
||||
# nr-poll-queues [OPTIONAL]
|
||||
# See definition in [Global] section. This is used to override
|
||||
# the value specified in the [Global] section.
|
||||
#
|
||||
# queue-size [OPTIONAL]
|
||||
# See definition in [Global] section. This is used to override
|
||||
# the value specified in the [Global] section.
|
||||
#
|
||||
# kato [OPTIONAL]
|
||||
# See definition in [Global] section. This is used to override
|
||||
# the value specified in the [Global] section.
|
||||
#
|
||||
# reconnect-delay [OPTIONAL]
|
||||
# See definition in [Global] section. This is used to override
|
||||
# the value specified in the [Global] section.
|
||||
#
|
||||
# ctrl-loss-tmo [OPTIONAL]
|
||||
# See definition in [Global] section. This is used to override
|
||||
# the value specified in the [Global] section.
|
||||
#
|
||||
# disable-sqflow [OPTIONAL]
|
||||
# See definition in [Global] section. This is used to override
|
||||
# the value specified in the [Global] section.
|
||||
#
|
||||
# Multiple DCs may be specified on separate lines like this (this is
|
||||
# just an example and does not represent default values):
|
||||
#
|
||||
# controller = transport=tcp;traddr=localhost;nqn=nqn.1988-11.com.dell:PowerSANxxx:01:20210225100113-454f73093ceb4847a7bdfc6e34ae8e28
|
||||
# controller = transport=tcp;traddr=2001:db8::370:7334;host-iface=enp0s8;nqn=nqn.starship-enterprise
|
||||
# controller = transport=fc;traddr=nn-0x204600a098cbcac6:pn-0x204700a098cbcac6;nqn=nqn.romulan-empire
|
||||
# ...
|
||||
# Type: String
|
||||
#
|
||||
# Default: There is no default controller. STAC will not try to
|
||||
# connect to a default I/O Controller.
|
||||
#controller=
|
||||
|
||||
|
||||
# exclude: Excluded controllers. This keyword allows configuring I/O
|
||||
# controllers that should not be connected to (whatever the
|
||||
# reason may be).
|
||||
#
|
||||
# The syntax is the same as for "controller=", except that the key
|
||||
# host-traddr does not apply. Multiple "exclude=" keywords may
|
||||
# appear in the config file to define the exclusion list.
|
||||
#
|
||||
# Note 1: A minimal match approach is used to eliminate unwanted
|
||||
# controllers. That is, you do not need to specify all the
|
||||
# parameters to identify a controller. Just specifying the
|
||||
# host-iface, for example, can be used to exclude all controllers
|
||||
# on an interface.
|
||||
#
|
||||
# Note 2: "exclude=" takes precedence over "controller=". A
|
||||
# controller specified by the "controller=" keyword, can be
|
||||
# eliminated by the "exclude=" keyword.
|
||||
#
|
||||
# Syntax: Same as "controller=" above.
|
||||
# Type: String
|
||||
#
|
||||
# Example:
|
||||
# exclude = transport=tcp;traddr=fe80::2c6e:dee7:857:26bb # Eliminate a specific address
|
||||
# exclude = host-iface=enp0s8 # Eliminate everything on this interface
|
||||
#exclude=
|
277
etc/stas/stafd.conf
Normal file
277
etc/stas/stafd.conf
Normal file
|
@ -0,0 +1,277 @@
|
|||
# Copyright (c) 2021, Dell Inc. or its subsidiaries. All rights reserved.
|
||||
# SPDX-License-Identifier: Apache-2.0
|
||||
# See the LICENSE file for details.
|
||||
#
|
||||
# This file is part of NVMe STorage Appliance Services (nvme-stas).
|
||||
|
||||
# ==============================================================================
|
||||
# STorage Appliance Finder Daemon (stafd) - configuration file
|
||||
#
|
||||
# In this file, options that are commented represent the default values used.
|
||||
# Uncommented options override the default value.
|
||||
|
||||
|
||||
[Global]
|
||||
# tron: Trace-ON. Enable additional debug info
|
||||
# Type: boolean
|
||||
# Range: [false, true]
|
||||
#tron=false
|
||||
|
||||
# hdr-digest: Protocol Data Unit (PDU) Header Digest. NVMe/TCP facilitates an
|
||||
# optional PDU Header digest. Digests are calculated using the
|
||||
# CRC32C algorithm.
|
||||
# Type: boolean
|
||||
# Range: [false, true]
|
||||
#hdr-digest=false
|
||||
|
||||
# data-digest: Protocol Data Unit (PDU) Data Digest. NVMe/TCP facilitates an
|
||||
# optional PDU Data digest. Digests are calculated using the
|
||||
# CRC32C algorithm.
|
||||
# Type: boolean
|
||||
# Range: [false, true]
|
||||
#data-digest=false
|
||||
|
||||
# kato: Keep Alive Timeout (KATO): This field specifies the timeout value
|
||||
# for the Keep Alive feature in seconds. The default value for this
|
||||
# field is 30 seconds.
|
||||
# Type: Unsigned integer
|
||||
# Range: 0..N
|
||||
# Unit: Seconds
|
||||
#kato=30
|
||||
|
||||
# queue-size: Overrides the default number of elements in the I/O queues
|
||||
# created by the driver.
|
||||
# Type: Unsigned integer
|
||||
# Range: 16..1024
|
||||
# Default: 128
|
||||
#queue-size=128
|
||||
|
||||
# reconnect-delay: Overrides the default delay, in seconds, before reconnect
|
||||
# is attempted after a connect loss.
|
||||
# Type: Unsigned integer
|
||||
# Range: 1..N
|
||||
# Unit: Seconds
|
||||
# Default: 10 (retry to connect every 10 seconds)
|
||||
#reconnect-delay=10
|
||||
|
||||
# ctrl-loss-tmo: Overrides the default controller loss timeout period in
|
||||
# seconds.
|
||||
# Type: Unsigned integer
|
||||
# Range: -1, 0..N where -1 means retry forever
|
||||
# Unit: Seconds
|
||||
# Default: 600 (retry to connect for up to 10 minutes)
|
||||
#ctrl-loss-tmo=600
|
||||
|
||||
# disable-sqflow: Disables SQ flow control to omit head doorbell update for
|
||||
# submission queues when sending nvme completions.
|
||||
# Type: boolean
|
||||
# Range: [false, true]
|
||||
# Default: false
|
||||
#disable-sqflow=false
|
||||
|
||||
# ignore-iface: This option controls whether connections with Discovery
|
||||
# Controllers (DC) will be forced on a specific interface or
|
||||
# will rely on the routing tables to determine the interface.
|
||||
#
|
||||
# See the man pages for details: man stafd.conf
|
||||
#
|
||||
# Type: boolean
|
||||
# Range: [false, true]
|
||||
# Default: true
|
||||
#ignore-iface=false
|
||||
|
||||
# ip-family: With this you can specify whether stafd will support IPv4, IPv6,
|
||||
# or both when connecting to Discovery Controllers (DC).
|
||||
#
|
||||
# See the man pages for details: man stafd.conf
|
||||
#
|
||||
# Type: String
|
||||
# Range: [ipv4, ipv6, ipv4+ipv6]
|
||||
# Default: ipv4+ipv6
|
||||
#ip-family=ipv4+ipv6
|
||||
|
||||
# pleo: Port Local Entries Only. If enabled and supported, when connected to a
|
||||
# Direct Discovery Controller (DDC), stafd will ask the DDC to return
|
||||
# records for only NVM subsystem ports that are presented through the same
|
||||
# NVM subsystem port that received the Get Log Page command. When disabled
|
||||
# or not supported by the DDC, the DDC may return NVM subsystems that are
|
||||
# not even reachable by the host, including those using a transport
|
||||
# different from the transport used for the Get Log Page command (e.g. Get
|
||||
# Log Page using TCP and receiving FC subsystems). This configuration
|
||||
# parameter has no effect if the DDC does not support PLEO (see PLEOS).
|
||||
#
|
||||
# Type: String
|
||||
# Range: [disabled, enabled]
|
||||
# Default: enabled
|
||||
#pleo=enabled
|
||||
|
||||
# ==============================================================================
|
||||
[Service Discovery]
|
||||
# zeroconf: Control whether DNS-SD/mDNS automatic discovery is enabled. This is
|
||||
# used to enable or disable automatic discovery of Discovery
|
||||
# Controllers using DNS-SD/mDNS.
|
||||
#
|
||||
# Type: String
|
||||
# Range: [disabled, enabled]
|
||||
# Default: enabled
|
||||
#zeroconf=enabled
|
||||
|
||||
# ==============================================================================
|
||||
[Discovery controller connection management]
|
||||
# persistent-connections: Whether connections to Discovery Controllers (DC)
|
||||
# are persistent. If stafd is stopped, the connections
|
||||
# will persists. When this is set to false, stafd will
|
||||
# disconnect from all DCs it is connected to when stafd
|
||||
# is stopped.
|
||||
# Type: boolean
|
||||
# Range: [false, true]
|
||||
#persistent-connections=true
|
||||
|
||||
# zeroconf-connections-persistence: DCs that are discovered with mDNS service
|
||||
# discovery which are later lost (i.e. no mDNS
|
||||
# and TCP connection fails), will be purged from
|
||||
# the configuration after this amount of time.
|
||||
# Type: Time specs.
|
||||
# Unit: Takes a unit-less value in seconds,
|
||||
# or a time span (TS) value such as
|
||||
# "3 days 5 hours".
|
||||
# Range: -1, 0, TS.
|
||||
# With "-1" equal to "no timeout" and
|
||||
# 0 equal to timeout immediately.
|
||||
# Default: 72 hours (3 days)
|
||||
#zeroconf-connections-persistence=72hours
|
||||
|
||||
# ==============================================================================
|
||||
[Controllers]
|
||||
# controller: Discovery Controllers (DC) are specified with this keyword.
|
||||
#
|
||||
# Syntax:
|
||||
# controller = transport=[trtype];traddr=[traddr];trsvcid=[trsvcid];host-traddr=[traddr];host-iface=[iface];nqn=<dcnqn>
|
||||
#
|
||||
# transport=<trtype> [MANDATORY]
|
||||
# This field specifies the network fabric being used for a NVMe-over-
|
||||
# Fabrics network. Current string values include:
|
||||
#
|
||||
# Value Definition
|
||||
# ------- -----------------------------------------------------------
|
||||
# rdma The network fabric is an rdma network (RoCE, iWARP,
|
||||
# Infiniband, basic rdma, etc)
|
||||
# fc The network fabric is a Fibre Channel network.
|
||||
# tcp The network fabric is a TCP/IP network.
|
||||
# loop Connect to a NVMe over Fabrics target on the local host
|
||||
#
|
||||
# traddr=<traddr> [MANDATORY]
|
||||
# This field specifies the network address of the Controller. For
|
||||
# transports using IP addressing (e.g. rdma) this should be an IP-
|
||||
# based address (ex. IPv4, IPv6). It could also be a resolvable host
|
||||
# name (e.g. localhost).
|
||||
#
|
||||
# nqn=<dcnqn> [OPTIONAL]
|
||||
# This field specifies the Discovery Controller's NVMe Qualified
|
||||
# Name. If not specified, this will default to the well-known DC
|
||||
# NQN: "nqn.2014-08.org.nvmexpress.discovery".
|
||||
#
|
||||
# trsvcid=<trsvcid> [OPTIONAL]
|
||||
# This field specifies the transport service id. For transports using
|
||||
# IP addressing (e.g. rdma) this field is the port number.
|
||||
#
|
||||
# Depending on the transport type, this field will default to either
|
||||
# 8009 or 4420 as follows.
|
||||
#
|
||||
# UDP port 4420 and TCP port 4420 have been assigned by IANA
|
||||
# for use by NVMe over Fabrics. NVMe/RoCEv2 controllers use UDP port
|
||||
# 4420 by default. NVMe/iWARP controllers use TCP port 4420 by
|
||||
# default.
|
||||
#
|
||||
# TCP port 4420 has been assigned for use by NVMe over Fabrics and TCP
|
||||
# port 8009 has been assigned by IANA for use by NVMe over Fabrics
|
||||
# discovery. TCP port 8009 is the default TCP port for NVMe/TCP
|
||||
# discovery controllers. There is no default TCP port for NVMe/TCP I/O
|
||||
# controllers, the Transport Service Identifier (TRSVCID) field in the
|
||||
# Discovery Log Entry indicates the TCP port to use.
|
||||
#
|
||||
# The TCP ports that may be used for NVMe/TCP I/O controllers include
|
||||
# TCP port 4420, and the Dynamic and/or Private TCP ports (i.e., ports
|
||||
# in the TCP port number range from 49152 to 65535). NVMe/TCP I/O
|
||||
# controllers should not use TCP port 8009. TCP port 4420 shall not be
|
||||
# used for both NVMe/iWARP and NVMe/TCP at the same IP address on the
|
||||
# same network.
|
||||
#
|
||||
# Ref: https://www.iana.org/assignments/service-names-port-numbers/service-names-port-numbers.xhtml?search=nvme
|
||||
#
|
||||
# host-traddr=<traddr> [OPTIONAL]
|
||||
# This field specifies the network address used on the host to connect
|
||||
# to the Controller. For TCP, this sets the source address on the
|
||||
# socket.
|
||||
#
|
||||
# host-iface=<iface> [OPTIONAL]
|
||||
# This field specifies the network interface used on the host to
|
||||
# connect to the Controller (e.g. IP eth1, enp2s0, enx78e7d1ea46da).
|
||||
# This forces the connection to be made on a specific interface
|
||||
# instead of letting the system decide.
|
||||
#
|
||||
# hdr-digest [OPTIONAL]
|
||||
# See definition in [Global] section. This is used to override
|
||||
# the value specified in the [Global] section.
|
||||
#
|
||||
# data-digest [OPTIONAL]
|
||||
# See definition in [Global] section. This is used to override
|
||||
# the value specified in the [Global] section.
|
||||
#
|
||||
# kato [OPTIONAL]
|
||||
# See definition in [Global] section. This is used to override
|
||||
# the value specified in the [Global] section.
|
||||
#
|
||||
# reconnect-delay [OPTIONAL]
|
||||
# See definition in [Global] section. This is used to override
|
||||
# the value specified in the [Global] section.
|
||||
#
|
||||
# ctrl-loss-tmo [OPTIONAL]
|
||||
# See definition in [Global] section. This is used to override
|
||||
# the value specified in the [Global] section.
|
||||
#
|
||||
# disable-sqflow [OPTIONAL]
|
||||
# See definition in [Global] section. This is used to override
|
||||
# the value specified in the [Global] section.
|
||||
#
|
||||
# Multiple DCs may be specified on separate lines like this (this is
|
||||
# just an example and does not represent default values):
|
||||
#
|
||||
# controller = transport=tcp;traddr=localhost;trsvcid=8009
|
||||
# controller = transport=tcp;traddr=2001:db8::370:7334;host-iface=enp0s8
|
||||
# controller = transport=fc;traddr=nn-0x204600a098cbcac6:pn-0x204700a098cbcac6
|
||||
# ...
|
||||
#
|
||||
# Type: String
|
||||
#
|
||||
# Default: There is no default controller. STAF will not try to
|
||||
# connect to a default Discovery Controller.
|
||||
#controller=
|
||||
|
||||
|
||||
# exclude: Excluded controllers. Using mDNS to automatically detect
|
||||
# and connect controllers, can result in unintentional connections
|
||||
# being made. This keyword allows configuring the controllers that
|
||||
# should not be connected to (whatever the reason may be).
|
||||
#
|
||||
# The syntax is the same as for "controller=", except that the key
|
||||
# host-traddr does not apply. Multiple "exclude=" keywords may
|
||||
# appear in the config file to define the exclusion list.
|
||||
#
|
||||
# Note 1: A minimal match approach is used to eliminate unwanted
|
||||
# controllers. That is, you do not need to specify all the
|
||||
# parameters to identify a controller. Just specifying the
|
||||
# host-iface, for example, can be used to exclude all controllers
|
||||
# on an interface.
|
||||
#
|
||||
# Note 2: "exclude=" takes precedence over "controller=". A
|
||||
# controller specified by the "controller=" keyword, can be
|
||||
# eliminated by the "exclude=" keyword.
|
||||
#
|
||||
# Syntax: Same as "controller=" above.
|
||||
# Type: String
|
||||
#
|
||||
# Example:
|
||||
# exclude = transport=tcp;traddr=fe80::2c6e:dee7:857:26bb # Eliminate a specific address
|
||||
# exclude = host-iface=enp0s8 # Eliminate everything on this interface
|
||||
#exclude=
|
62
etc/stas/sys.conf.doc
Normal file
62
etc/stas/sys.conf.doc
Normal file
|
@ -0,0 +1,62 @@
|
|||
# Copyright (c) 2022, Dell Inc. or its subsidiaries. All rights reserved.
|
||||
# SPDX-License-Identifier: Apache-2.0
|
||||
# See the LICENSE file for details.
|
||||
#
|
||||
# This file is part of NVMe STorage Appliance Services (nvme-stas).
|
||||
|
||||
# ==============================================================================
|
||||
# STorage Appliance Services (stas) - System configuration file
|
||||
#
|
||||
# In this file, options that are commented represent the default values used.
|
||||
# Uncommented options override the default value.
|
||||
|
||||
|
||||
[Host]
|
||||
# nqn: The host's unique Non-Qualified Name. A value starting with "file://"
|
||||
# indicates that the Host NQN can be retrieved from a separate file.
|
||||
# Typically, nvme-cli saves the Host NQN in /etc/nvme/hostnqn. For
|
||||
# compatibility with nvme-cli, nvme-stas defaults to looking for the
|
||||
# existance of this file and will read the NQN from it. Otherwise, you
|
||||
# can overwrite the default NQN by specifying its value here or
|
||||
# specifying another file that contains the Host NQN to use.
|
||||
# Type: string
|
||||
# Default: file:///etc/nvme/hostnqn
|
||||
#nqn=file:///etc/nvme/hostnqn
|
||||
|
||||
|
||||
# id: The host's unique Identifier (ID). A value starting with "file://"
|
||||
# indicates that the Host ID can be retrieved from a separate file.
|
||||
# Typically, nvme-cli saves the Host ID in /etc/nvme/hostid. For
|
||||
# compatibility with nvme-cli, nvme-stas defaults to looking for the
|
||||
# existance of this file and will read the ID from it. Otherwise, you
|
||||
# can overwrite the default ID by specifying its value here or
|
||||
# specifying another file that contains the Host ID to use.
|
||||
# Type: string
|
||||
# Default: file:///etc/nvme/hostid
|
||||
#id=file:///etc/nvme/hostid
|
||||
|
||||
|
||||
# key: The host's DHCHAP key to be used for authentication. This is an
|
||||
# optional parameter only required when authentication is needed.
|
||||
# A value starting with "file://" indicates that the Host Key can
|
||||
# be retrieved from a separate file. Typically, nvme-cli saves the
|
||||
# Host Key in /etc/nvme/hostkey. For compatibility with nvme-cli,
|
||||
# nvme-stas defaults to looking for the existance of this file and
|
||||
# will read the Key from it. Otherwise, you can overwrite the default
|
||||
# Key by specifying its value here or specifying another file that
|
||||
# contains an alternate Host Key to use.
|
||||
# Type: string
|
||||
# Default: file:///etc/nvme/hostkey
|
||||
#key=file:///etc/nvme/hostkey
|
||||
|
||||
|
||||
# symname: The host's symbolic name. This can be a string or the name of a file
|
||||
# containing the symbolic name. A value starting with "file://"
|
||||
# indicates that the Symbolic Name can be retrieved from a separate
|
||||
# file.
|
||||
# Type: string
|
||||
# Default: There is no default. The symbolic name is undefined by
|
||||
# default.
|
||||
#symname=
|
||||
|
||||
|
Loading…
Add table
Add a link
Reference in a new issue